Rapid electrochemiluminoimmunoassay of human C-reactive protein at planar disposable oxide-coated silicon electrodes.

نویسندگان

  • Timo Ala-Kleme
  • Piia Mäkinen
  • Tiina Ylinen
  • Leif Väre
  • Sakari Kulmala
  • Petri Ihalainen
  • Jouko Peltonen
چکیده

Electrochemiluminescence (ECL) of aromatic Tb(III) chelates at thin insulating film-coated electrodes provides a means for extremely sensitive detection of Tb(III) chelates and also of biologically interesting compounds if these chelates are used as labels in bioaffinity assays. The suitability of silicon electrodes coated with thermally grown silicon dioxide film as disposable working electrodes in sensitive time-resolved ECL measurements is demonstrated, and a rapid electrochemiluminoimmunoassay (ECLIA) of human C-reactive protein (hCRP) is described. Tb(III) chelate labels can be detected almost down to picomolar level, and the calibration curve of these labels covers more than 6 orders of magnitude of chelate concentration. The calibration curve of the present immunometric hCRP assay was found to be linear over a wide range, approximately 4 orders of magnitude of hCRP concentration, the detection limit of the protein being 0.3 ng mL(-1) (mean background + 2SD) on CV values of about 10-30%, depending on the immunoassay incubation time. In the ECLIA measurements, different incubation times were tested from 15 min (giving above-mentioned performance) to as short as only 2 min, which still gave successful results with approximately 20,000 times better detection limit levels than traditional commercial assay methods. During the ECLIA process, also the Si electrode surface morphology was also investigated by atomic force microscope monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and fabrication of a rapid conductometric pH sensor based on metal-oxide technology

A micro-fabricated metal-oxide based conductometric pH sensor is designed and fabricated in this manuscript. pH sensors have applications in various areas from farming to food processing, human health monitoring, industrial waste products investigation, etc. Accordingly, there is a relatively high demand for a reliable, rapid and precise pH sensor in the market. Relatively precise pH sensors ha...

متن کامل

Electrochemical Determination of Neonicotinoid Insecticide Clothianidin by Nanomaterial based Disposable Electrode

Disposable, selective and low-cost carbon nanotube modified electrodes were fabricated for the electrochemical detection of neonicotinoid insecticide, Clothianidin (CLT). Almost 2 folds’ increase at Clothianidin reduction signal was obtained by using single-walled carbon nanotube modified electrodes (SWCNT-PGE) compared to unmodified electrodes. These nanomaterials modified electrodes developed...

متن کامل

Using nanostructured conductive carbon tape modified with bismuth as the disposable working electrode for stripping analysis in paper-based analytical devices.

Low cost disposable working electrodes are specifically desired for practical applications of electrochemical detection considering maturity of electrochemical stations and data collection protocols. In this paper double-sided conductive adhesive carbon tape with nanostructure was applied to fabricate disposable working electrodes. Being supported by indium tin oxide glass, the prepared carbon ...

متن کامل

Hot electron-induced cathodic electrochemiluminescence of rhodamine B at disposable oxide-coated aluminum electrodes

Rhodamine B (RhB) exhibits strong cathodic electrogenerated chemiluminescence (ECL) in aqueous solutions during high-amplitude p l l e w s ©

متن کامل

Improvement of a Nano-scale Silicon on Insulator Field Effect Transistor Performance using Electrode, Doping and Buried Oxide Engineering

In this work, a novel Silicon on Insulator (SOI) MOSFET is proposed and investigated. The drain and source electrode structures are optimized to enhance ON-current while global device temperature and hot carrier injection are decreased. In addition, to create an effective heat passage from channel to outside of the device, a silicon region has embedded in the buried oxide. In order to reduce th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 2006