Wavelet-based partial volume effect correction for simultaneous MR/PET of the carotid arteries
نویسندگان
چکیده
Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, NY, NY, USA Simultaneous MR/PET scanners allow for the exploration and development of novel PVE correction techniques without the challenges of coregistration of MR and PET. The development of a wavelet-based PVE correction method, to improve PET quantification, has proven successful in brain PET. We report here the first attempt to apply these methods to simultaneous MR/PET imaging of the carotid arteries. The American College of Radiology (ACR) phantom was injected with 18F-FDG for a lesion to background ratio of 2.5. As per ACR protocol, hot cylinders (“lesions”) were injected with 30.71MBq and the phantom background was injected with 12.95MBq. The ACR phantom was then scanned on the Siemens mCT and Siemens Biograph mMR. One patient was injected with 446.6MBq of 18F-FDG and scanned after a circulation time of 90 minutes on the Siemens Biograph mMR. The MR/PET acquisition consisted of the system standard Dixon attenuation correction sequence. Wavelet-based PVE correction was performed to incorporate high frequency wavelet information from MR images into PET images to improve resolution. Qualitative and quantitative uptake parameters where measured to assess the efficacy of the method used. Qualitative comparisons in the ACR phantom and a patient without and with wavelet-based PVE correction demonstrated slight improvement in image quality. Line profiles drawn through the 8mm cylinder and 25mm cylinder and demonstrated an improvement of quantification in the wavelet-based PVE corrected PET image compared to the non-corrected PET image. Standard deviation of SUV before and after PVE correction in the left and right carotid arteries was decreased demonstrating partial volume effect correction. The technique applied here demonstrated an improvement in both resolution and quantification in the phantom and the patient. These results demonstrate the feasibility of wavelet-based PVE correction to provide improved quantification for MR/PET in the carotid arteries.
منابع مشابه
Feasibility of simultaneous PET/MR of the carotid artery: first clinical experience and comparison to PET/CT.
The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of (18)F-FDG. PET/MR was performed a median of 131 min after injection. Subsequently,PET/CT was performed. Regions of interest (ROI) were drawn slice...
متن کاملComparison of methods for magnetic resonance-guided [18-F]fluorodeoxyglucose positron emission tomography in human carotid arteries: reproducibility, partial volume correction, and correlation between methods.
BACKGROUND AND PURPOSE Inflammation is a major risk factor for atherosclerotic plaque rupture and clinical events. Previous studies have shown that plaque [(18)F]fluorodeoxyglucose (FDG) uptake correlates with macrophage content. In this study we examined the reproducibility of 3 methods of quantifying plaque FDG uptake in the carotid arteries using positron emission tomography (PET). The corre...
متن کاملEffect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملEstimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method.
Kinetic analysis of 18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image derived input function is a non-invasive alternative but is challenging due to partial volume effects ca...
متن کاملDo carotid MR surface coils affect PET quantification in PET/MR imaging?
Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to...