Parametric study on the behaviour of bolted composite connections Estudo paramétrico do comportamento de ligações mistas parafusadas
نویسنده
چکیده
© 2012 IBRACON The studied connections are composed of concrete filled steel tubes (CFT) connected to composite beams by passing through bolts, endplates and steel deck, which also contributes to support the applied loads. The parametric analysis presented in this work is based on numerical simulations performed with software TNO Diana, using experimental results to calibrate the reference numerical model. The influence of three main parameters, being them the bolts diameter, the slab height and the beams cross section, was evaluated. According to the obtained bending moment versus rotation curves, it was concluded that, among the three parameters analyzed, the most important one was the bolts diameter. About the beams cross section, inconclusive results were achieved, probably due to the incompatibility between the 16 mm bolts and the robust beam cross sections considered in the parametric analysis.
منابع مشابه
Finite Element Analysis on Tensile Stiffness of Cold-Formed Steel Bolted Connections
This paper presents a finite element analysis on the tensile stiffness of steel bolted connections, which are fabricated from thin-walled cold-formed steel strips and members. This type of bolted connection is usually used to assemble the diagonal bracing member in the light steel structure. Unlike the architectural steel structure, thin walled steel bolted connection cannot be simplified into ...
متن کاملViolent behavior during sleep Violência durante o sono
Casos de comportamento violento (CV) durante o sono são relatados na literatura. A incidência de comportamento violento durante o sono não é muito conhecida. Um estudo epidemiológico mostra que cerca de 2% da população geral apresentava comportamento violento dormindo e eram predominantemente homens. Neste artigo, os autores descrevem aspectos clínicos e médico-legais envolvidos na investigação...
متن کاملExperimental Study for Strength Capacity of Cold-Formed Steel Joists Connections with Consideration of Various Bolts Arrangements
With growth the construction technologies, Cold-Formed Steel, CFS, sections are widely used in ordinary steel buildings because of some advantages such as light weight, ease of installation, decrease in cost, and increase in speed of operation. Using the bolted connections for CFS joist is one of the best details for steel structures. The main objective of this study is to conduct an experiment...
متن کاملA Study on the Ductility of Bolted Beam - Column Connections
The behaviour of beam-column joint plays an important role in the response of a steel moment resisting framed structure especially under seismic excitation. Semi rigid connections like bolted joints, allow better energy dissipation and provide good response under lateral loads. In this paper the ductility and energy dissipation characteristics of semi rigid bolted connections using double web a...
متن کاملInfluential Factor in Improving the Seismic Performance of the Kaiser Bolted Bracket Moment Connection
Following the Northridge earthquake of 1994, a significant number of steel moment resisting structural systems were damaged. Several studies have been conducted to improve the seismic performance of steel structures and specially their beam-to-column connections. One of the proposed connections for special moment-resisting frames included AISC-358 is Kaiser bolted bracket moment connection, bri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012