Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus.
نویسندگان
چکیده
The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.
منابع مشابه
Tomographic Analysis of Neutron and Gamma Pulse Shape Distributions from Liquid Scintillation Detectors at JET
متن کامل
A first comparison of the responses of a He-based fast-neutron detector and a NE-213 liquid-scintillator reference detector
A first comparison has been made between the pulse-shape discrimination characteristics of a novel He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neu...
متن کاملNeutron and gamma-ray cross-correlation measurements of plutonium oxide powder
For the first time, measurements of the time-dependent cross-correlation distributions of plutonium oxide have been made separately for neutrons and gamma rays. Six EJ-309 liquid scintillation detectors with a digital, offline pulse shape discrimination and pulse timing method were used to measure five different samples of varying mass and burnup. The number of (neutron, neutron) correlations w...
متن کاملDigital Data Acquisition System for Time of Flight Neutron Beam Measurements
Rensselaer Polytechnic Institute: Gaerttner LINAC Laboratory, Troy, New York, 12180, [email protected] INTRODUCTION A system for neutron scattering measurements is under development at the RPI LINAC [1]. The system is design to provide additional differential scattering data to improve upon the currently available cross section data. The system is designed to work in the energy range of 0.2-20 MeV...
متن کاملشبیهسازی تابع پاسخ سوسوزنهای آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL
In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 85 2 شماره
صفحات -
تاریخ انتشار 2014