Multicenter Analytical Evaluation of the Automated Electrochemiluminescence Immunoassay for Cyclosporine
نویسندگان
چکیده
BACKGROUND Cyclosporine A (CsA) is used as a posttransplantation immunosuppressant drug, and careful monitoring of CsA concentration in whole blood is essential. A new automated electrochemiluminescence immunoassay (ECLIA) for CsA measurement has been assessed in a multicenter evaluation. METHODS Residual EDTA whole blood samples from patients undergoing CsA therapy after organ transplant were used in assay evaluation at 5 clinical laboratories in Europe. Experiments included imprecision according to CLSI EP5-A2 (within-run and intermediate), lower limit of quantification, linearity according to CLSI EP6-A, and recovery of commercial external quality control samples. In addition, comparisons to liquid chromatography-tandem mass spectrometry methods in routine use at each investigational site and to commercial chemiluminescent microparticle immunoassay and antibody-conjugated magnetic immunoassay methods were performed. RESULTS Imprecision testing gave coefficients of variation of less than 9% in the 30-2000 mcg/L range for both within-run and intermediate imprecision. Lower limit of quantification of 6.8 mcg/L at one investigational site and 1.8 mcg/L at a second site at 20% coefficient of variation were observed. Linearity was measured over the concentration range 0-2000 mcg/L, yielding a deviation of less than ±12%. External quality control sample recovery by ECLIA was 93%-114% of LC-MS/MS sample recovery. Deming regression analysis of ECLIA method comparison to combined LC-MS/MS results yielded a slope of 1.04 [95% confidence interval (CI), 1.03-1.06] and intercept of 2.8 mcg/L (95% CI, 1.5-4.1 mcg/L). Comparison to chemiluminescent microparticle immunoassay yielded a slope of 0.87 (95% CI, 0.85-0.89) and intercept of 1.4 mcg/L (95% CI, -0.89 to 3.7 mcg/L); comparison to antibody-conjugated magnetic immunoassay yielded a slope of 0.96 (95% CI, 0.93-0.98) and intercept of -4.2 mcg/L (95% CI, -7.1 to -1.2 mcg/L). CONCLUSIONS The data from this multicenter evaluation indicate that the new ECLIA-based cyclosporine assay is fit for its purpose, the therapeutic monitoring of CsA.
منابع مشابه
Multi-center Performance Evaluations of Tacrolimus and Cyclosporine Electrochemiluminescence Immunoassays in the Asia-Pacific Region
BACKGROUND The immunosuppressant drugs (ISDs), tacrolimus and cyclosporine, are vital for solid organ transplant patients to prevent rejection. However, toxicity is a concern, and absorption is highly variable across patients; therefore, ISD levels need to be precisely monitored. In the Asia-Pacific (APAC) region, tacrolimus and cyclosporine concentrations are typically measured using immunoass...
متن کاملAnalytical performance evaluation of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assays on the cobas e411 analyzer
BACKGROUND Cyclosporine (CsA) and tacrolimus (TAC) are immunosuppressant drugs that are often used to treat autoimmune diseases and as transplantation therapy; therefore, their concentrations need to be monitored carefully. We herein evaluated the analytical performance of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assay kits, which have been newly developed to measure CsA and TAC concen...
متن کاملEvaluation of electrochemiluminescence immunoassays for immunosuppressive drugs on the Roche cobas e411 analyzer
Background: Therapeutic drug monitoring of immunosuppressant drugs are used to monitor drug efficacy and toxicity and to prevent organ transplantation rejection. This study evaluates the analytical performance of semi-automated electrochemiluminescence immunoassays (ECLIA) for cyclosporine (CSA), tacrolimus (TAC) and sirolimus (SRL) on the Roche cobas e 411 analyzer at a major transplant hospi...
متن کاملPerformance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملAnalytical and clinical evaluation of an electrochemiluminescence immunoassay for the determination of CA 125.
The CA 125 II assay on the Elecsys(R) 2010 analyzer was evaluated in an international multicenter trial. Imprecision studies yielded within-run CVs of 0.8-3.3% and between-day CVs of 2.4-10.9%; CVs for total imprecision in the manufacturer's laboratory were 2.4-7.8%. The linear range of the assay extended to at least 4500 kilounits/L (three decades). Interference from triglycerides (10.3 mmol/L...