Background LGE-MRI is widely used to assess cardiac RF ablation lesions. However, LGE-MRI requires contrast injection and the appearance, dimensions and visibility of lesions in LGE-MRI noticeably change with time after ablation and time after contrast injection. Recently proposed non-contrast T1-weighted (T1w) technique is only applicable to visualize acute (< 3 days) RF lesions. The main goal of this study was to develop and validate a non-contrast MRI technique for assessment of sub-acute (> 3 days) RF ablations.
منابع مشابه
Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla.
BACKGROUND Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. OBJECTIVE The purpose of this ...
متن کاملVisualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging.
BACKGROUND The purpose of this study was to describe a system and method for creating, visualizing, and monitoring cardiac radiofrequency ablation (RFA) therapy during magnetic resonance imaging (MRI). METHODS AND RESULTS RFA was performed in the right ventricular apex of 6 healthy mongrel dogs with a custom 7F nonmagnetic ablation catheter (4-mm electrode) in a newly developed real-time inte...
متن کاملI-45: Advance MRI Sequences in Pelvic Endometriosis
Background: To assess MRI in diagnosing endometriotic lesions, emphasizing T2*weighted imaging efficacy. Materials and Methods: This prospective study of 48 females (22-38 years, average 29.6) clinically suspected of endometriosis from September 2009 to April 2012. MRI was performed with a 1.5 T imager (Siemens) with a body array coil. T1, T2 and T2* weighted (2D-FLASH) sequences were obtained ...
متن کاملFeasibility of contrast-enhanced and nonenhanced MRI for intraprocedural and postprocedural lesion visualization in interventional electrophysiology: animal studies and early delineation of isthmus ablation lesions in patients with typical atrial flutter.
BACKGROUND Imaging of myocardial ablation lesions during electrophysiology procedures would enable superior guidance of interventions and immediate identification of potential complications. The aim of this study was to establish clinically suitable MRI-based imaging techniques for intraprocedural lesion visualization in interventional electrophysiology. METHODS AND RESULTS Interventional ele...
متن کاملEvaluation of MRI protocols for the assessment of lumbar facet joints after MR-guided focused ultrasound treatment
BACKGROUND MR-guided focused ultrasound (MRgFUS) might be a very safe and effective minimally invasive technique to treat facet joint pain caused by arthritis and other degenerative changes. However, there are still safety concerns for this treatment and challenges regarding MR imaging and temperature mapping due to susceptibility effects between the bone and soft tissue near the joint, which h...