Fibre-optic aided bougie (FAB) for simulated difficult tracheal intubation.

نویسندگان

  • J W Chiu
  • M H Goh
  • P C Ip-Yam
چکیده

INTRODUCTION Difficult intubation remains a key problem and the value of the gum elastic bougie as a first approach is well recognised. MATERIALS AND METHODS A fine fibre-optic endoscope (Rapiscope, Cook Critical Care) was used in 50 patients to verify placement of a custom-designed hollow plastic bougie prior to "rail-roading" a tracheal tube. Following induction and muscle relaxation, direct laryngoscopy was performed after two-minutes of assisted ventilation. The laryngoscope blade was lowered to simulate difficult intubation and the bougie passed behind the epiglottis. The position of the introducer bougie was then checked using the Rapiscope. Following correct bronchoscopic identification of the tracheobronchial anatomy, a tracheal tube was then "rail-roaded" following withdrawal of the scope. RESULTS All patients were successfully intubated following identification of the bronchial tree by the Rapiscope: three on the second attempt and the rest on the first. Mean (SD, range) time to successful bronchoscopic confirmation of correct placement of the bougie was 38 s (9.1 s, 19 to 60 s). All bronchoscopic assisted intubation were subsequently confirmed by capnography after tracheal tube insertion. Mean (SD, range) time to successful intubation was 106 s (14 s, 52 to 132 s). CONCLUSION The fibre-optic assisted bougie (FAB) offers a promising technique in patients who may be difficult to intubate but who can be ventilated. Further developments are required to achieve a faster intubation time but oxygenation may be achieved by jetting down the hollow bougie.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscope-aided retrograde placement of guide wire for tracheal intubation in patients with limited mouth opening.

Passing a retrograde catheter/wire into the pharynx through a cricothyroid puncture can facilitate tracheal intubation in difficult situations where either a flexible fibre-optic bronchoscope or an expert user of such a device is not available. Some mouth opening is essential for the oral and/or nasal retrieval of the catheter/wire from the pharynx. Two patients with temporo-mandibular joint (T...

متن کامل

Utility of a Gum-Elastic Bougie for Difficult Airway Management in Infants: A Simulation-Based Crossover Analysis

BACKGROUND Direct laryngoscopy with the Miller laryngoscope (Mil) for infant tracheal intubation is often difficult to use even for skilled professionals. We performed a simulation trial evaluating the utility of a tracheal tube introducer (gum-elastic bougie (GEB)) in a simulated, difficult infant airway model. METHODS Fifteen anesthesiologists performed tracheal intubation on an infant mani...

متن کامل

Comparison of the Levitan FPS Scope and the single-use bougie for simulated difficult intubation in anaesthetised patients.

A randomised cross-over study was performed in 34 patients with no evidence of airway difficulties, following induction of general anaesthesia, to compare the efficacy of the Levitan FPS scope (LFPS) and the single-use bougie for tracheal intubation during simulated grade IIIa laryngoscopy. Success rates for intratracheal placement of the device, and the time required for insertion and tracheal...

متن کامل

Airway scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility.

BACKGROUND /st> Airway Scope is a new videolaryngoscope which requires less cervical movement during intubation than direct laryngoscopy. Thus, in patients wearing a rigid cervical collar, we compared the efficacy of the Airway Scope and the gum elastic bougie with Macintosh laryngoscope during tracheal intubation. METHODS /st> Anaesthesia was induced with propofol, fentanyl, and rocuronium. ...

متن کامل

Airway management complications in children with difficult tracheal intubation from the Pediatric Difficult Intubation (PeDI) registry: a prospective cohort analysis.

BACKGROUND Despite the established vulnerability of children during airway management, remarkably little is known about complications in children with difficult tracheal intubation. To address this concern, we developed a multicentre registry (Pediatric Difficult Intubation [PeDI]) to characterise risk factors for difficult tracheal intubation, establish the success rates of various tracheal in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2000