Anatomy, Variants, and Pathologies of the Superior Glenohumeral Ligament: Magnetic Resonance Imaging with Three-Dimensional Volumetric Interpolated Breath-Hold Examination Sequence and Conventional Magnetic Resonance Arthrography

نویسندگان

  • Hayri Ogul
  • Leyla Karaca
  • Cahit Emre Can
  • Berhan Pirimoglu
  • Kutsi Tuncer
  • Murat Topal
  • Aylin Okur
  • Mecit Kantarci
چکیده

The purpose of this review was to demonstrate magnetic resonance (MR) arthrography findings of anatomy, variants, and pathologic conditions of the superior glenohumeral ligament (SGHL). This review also demonstrates the applicability of a new MR arthrography sequence in the anterosuperior portion of the glenohumeral joint. The SGHL is a very important anatomical structure in the rotator interval that is responsible for stabilizing the long head of the biceps tendon. Therefore, a torn SGHL can result in pain and instability. Observation of the SGHL is difficult when using conventional MR imaging, because the ligament may be poorly visualized. Shoulder MR arthrography is the most accurately established imaging technique for identifying pathologies of the SGHL and associated structures. The use of three dimensional (3D) volumetric interpolated breath-hold examination (VIBE) sequences produces thinner image slices and enables a higher in-plane resolution than conventional MR arthrography sequences. Therefore, shoulder MR arthrography using 3D VIBE sequences may contribute to evaluating of the smaller intraarticular structures such as the SGHL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality.

PURPOSE To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination. MATERIALS AND METHODS Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; inter...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافته‌های Magnetic Resonance Imaging

Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...

متن کامل

I-59: Diagnostic Accuracy of Physical Examination,Transvaginal Sonography, RectalEndoscopic Sonography, and Magnetic ResonanceImaging to Diagnose Deep InfiltratingEndometriosis

Background: To compare the value of physical examination, transvaginal sonography (TVS), rectal endoscopic sonography (RES), and magnetic resonance imaging (MRI) for the assessment of different locations of deep infiltrating endometriosis (DIE). Materials and Methods: Ninety-two consecutive patients with clinical evidence of pelvic endometriosis. Physical examination, TVS, RES, and MRI, perform...

متن کامل

Impact of diet on stool signal in dark lumen magnetic resonance colonography.

PURPOSE To examine the magnetic resonance (MR) properties of different foods and their effect on the colonic stool signal to potentially support fecal tagging strategies for dark lumen MR colonography (MRC). MATERIALS AND METHODS T1 relaxation times of 120 different foods (partially diluted with sufficient water) were determined by use of a multi-flip-angle two-dimensional gradient echo (GRE)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014