Diagnosis and Treatment Algorithm for Blood Flow Obstructions in Patients With Left Ventricular Assist Device.
نویسندگان
چکیده
BACKGROUND Thrombosis is an uncommon, but severe complication of left ventricular assist devices (LVADs). OBJECTIVES This study analyzed experience with obstruction of blood flow through the LVAD with the purpose of developing optimal diagnosis and treatment of LVAD-related thrombosis. METHODS Between October 2009 and July 2015, a total of 652 LVAD were implanted in 557 patients. Blood flow abnormalities in patients with LVAD (n = 524) were identified and classified as "high-power" and "low-flow" events. RESULTS Three types of late blood flow obstructions were identified: 1) pre-pump via thrombus obstructing the inflow cannula (26 events; 0.037 events per patient-year); 2) intra-pump (70 events; 0.1 events per patient-year); and 3) post-pump via thrombosis of the outflow graft or stenosis of the anastomosis to the aorta (4 events; 0.006 events per patient-year). Pre-pump obstruction was treated by washout maneuver in 9 cases (success rate, 100%), thrombolysis in 9 patients (success rate, 56%), and pump exchange in 9 cases (success rate, 100%); 1 patient died without treatment and 2 were weaned from LVAD. Intra-pump obstruction was treated by thrombolysis (n = 9; success rate, 33%), pump exchange (n = 53; success rate, 94%), and removal due to myocardial recovery (n = 3; success rate, 100%); 7 patients died without treatment and parameters spontaneously normalized in 2 cases. Post-pump obstruction was treated in 2 patients by stenting (success rate, 100%), and was left untreated in 2 cases. CONCLUSIONS We identified 3 types of LVAD-related blood flow obstruction, and developed an algorithm for optimal diagnosis and treatment.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملLeft ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.
OBJECTIVE Fixed pulmonary hypertension is a contraindication for cardiac transplantation because of the increased risk of donor heart failure. We sought to determine whether left ventricular assist devices improve fixed pulmonary hypertension in cardiac transplant candidates to enable safe cardiac transplantation. METHODS Thirty-five consecutive cardiac transplant candidates (age 56 +/- 6 yea...
متن کاملBeneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation
BACKGROUND Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility. This is possible by real-time pump blood flow measurements. CLINICAL CASE We performed implantation of a continuous flow left ventricular assist device in a 66 years old female patient with an en...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 67 23 شماره
صفحات -
تاریخ انتشار 2016