Optimization of breast cancer excision by intraoperative ultrasound and marking needle - technique description and feasibility

نویسندگان

  • Nebojsa S Ivanovic
  • Darko D Zdravkovic
  • Zlatko Skuric
  • Jelena Kostic
  • Natasa Colakovic
  • Miodrag Stojiljkovic
  • Svetlana Opric
  • Magdalena Stefanovic Radovic
  • Ivan Soldatovic
  • Biljana Sredic
  • Miroslav Granic
چکیده

BACKGROUND We present a surgical technique and the preliminary results of breast cancer excision after insertion of a specially constructed marking needle into the tumor, controlled by intraoperative ultrasound. Resection margins were projected in six directions by ultrasound measurements, determined in relation to the needle, and resection was done in accordance with those measurements. The main objective was to obtain resection margins similar (equal) to those projected by intraoperative ultrasound (10 mm). METHODS Detailed description of the technique is given. Thirty-two female patients undergoing breast-conserving surgery, up to 30 mm in diameter, for palpable and non-palpable invasive breast cancer, were operated on using this technique. Its feasibility was tested by analyzing the success (rate) of needle placement in the tumor, the measurements executed, and the performance of the excision. RESULTS All stages of the technique were successfully performed to completion on all 32 patients. The procedure of needle placement and ultrasound measurement of distances took 11 min on average (between 6 and 20 min). The average distance of the tumor margin from the resection margin was 12.9 mm (2 to 30 mm, 95% confidence interval [11.9, 14.06]). There was one patient with a positive resection margin (3%). CONCLUSIONS The technique of excising palpable and non-palpable breast cancer by intraoperative ultrasound and an especially constructed marking needle is feasible and comfortable to perform. Preliminary results imply that resection volume can be rationalized, with the same or better oncological safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immersion Ultrasonography of Excised Nonpalpable Breast Lesion Specimens after Ultrasound-Guided Needle Localization

OBJECTIVE Ultrasound-guided needle localization has been used prior to the surgical excision of nonpalpable breast lesions. The aim of the study was to assess the feasibility of the use of a saline immersion specimen ultrasound technique (immersion-US) to confirm the successful removal of breast lesions. MATERIALS AND METHODS The devised immersion-US technique was used to examine the excised ...

متن کامل

The Core Needle and Surgical Biopsy Concordance to Detect Estrogen, Progesterone, and Her-2 Receptors in Breast Cancer: A Comparative Study

Background &Objectives;: Evaluation of estrogen receptor (ER), progesterone receptor (PR), and (human epidermal growth factor receptor-2) Her-2 on core needle biopsies (CNBs) is increasingly in use to diagnosis early breast cancer, but its concordance with surgical excision (SE) is not well documented. Methods: The study ...

متن کامل

A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model

Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We devel...

متن کامل

Intraoperative ultrasound reduces the need for re-excision in breast-conserving surgery

BACKGROUND The purpose of this study was to evaluate ultrasound-guided surgery for palpable breast cancer by comparing the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumor-free margins, and cosmetic outcomes. METHODS This was a prospective, observational cohort study conducted from January 2009 to July 2011. Breast cancer pat...

متن کامل

Evaluation of Newly Adapted Clip Marker System in Ultrasound-Guided Core Needle Biopsy for Suspicion of Breast Cancer.

Introduction: A newly adapted clip system for intramammary marking during ultrasound-guided core needle biopsy for suspicion of breast cancer is described and evaluated here. Material and Method: Fifty patients with suspicion of breast cancer (cT2) had ultrasound-guided core needle biopsy using a newly adapted clip marker system (HistoCore™ and O-Twist Marker™). Subsequently, ultrasound follow-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2015