Validation of a deformable image registration produced by a commercial treatment planning system in head and neck.

نویسندگان

  • Rafael García-Mollá
  • Noelia de Marco-Blancas
  • Jorge Bonaque
  • Laura Vidueira
  • Juan López-Tarjuelo
  • José Perez-Calatayud
چکیده

In recent years one of the areas of interest in radiotherapy has been adaptive radiation therapy (ART), with the most efficient way of performing ART being the use of deformable image registration (DIR). In this paper we use the distances between points of interest (POIs) in the computed tomography (CT) and the cone beam computed tomography (CBCT) acquisition images and the inverse consistence (IC) property to validate the RayStation treatment planning system (TPS) DIR algorithm. This study was divided into two parts: Firstly the distance-accuracy of the TPS DIR algorithm was ascertained by placing POIs on anatomical features in the CT and CBCT images from five head and neck cancer patients. Secondly, a method was developed for studying the implication of these distances on the dose by using the IC. This method compared the dose received by the structures in the CT, and the structures that were quadruply-deformed. The accuracy of the TPS was 1.7 ± 0.8 mm, and the distance obtained with the quadruply-deformed IC method was 1.7 ± 0.9 mm, i.e. the difference between the IC method multiplied by two, and that of the TPS validation method, was negligible. Moreover, the IC method shows very little variation in the dose-volume histograms when comparing the original and quadruply-deformed structures. This indicates that this algorithm is useful for planning adaptive radiation treatments using CBCT in head and neck cancer patients, although these variations must be taken into account when making a clinical decision to adapt a treatment plan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Learning anatomy changes from patient populations to create artificial CT images for voxel‐level validation of deformable image registration

The purpose of this study was to develop an approach to generate artificial computed tomography (CT) images with known deformation by learning the anatomy changes in a patient population for voxel-level validation of deformable image registration. Using a dataset of CT images representing anatomy changes during the course of radiation therapy, we selected a reference image and registered the re...

متن کامل

Evaluation of Deformable Image Registration-Based Contour Propagation From Planning CT to Cone-Beam CT

PURPOSE We evaluated the performance of organ contour propagation from a planning computed tomography to cone-beam computed tomography with deformable image registration by comparing contours to manual contouring. MATERIALS AND METHODS Sixteen patients were retrospectively identified based on showing considerable physical change throughout the course of treatment. Multiple organs in the 3 reg...

متن کامل

Validation of a dose warping algorithm using clinically realistic scenarios

OBJECTIVE Dose warping following deformable image registration (DIR) has been proposed for interfractional dose accumulation. Robust evaluation workflows are vital to clinically implement such procedures. This study demonstrates such a workflow and quantifies the accuracy of a commercial DIR algorithm for this purpose under clinically realistic scenarios. METHODS 12 head and neck (H&N) patien...

متن کامل

Deformable versus rigid registration of PET/CT images for radiation treatment planning of head and neck and lung cancer patients: a retrospective dosimetric comparison

BACKGROUND The purpose of this study is to evaluate the clinical impact of using deformable registration in tumor volume definition between separately acquired PET/CT and planning CT images. METHODS Ten lung and 10 head and neck cancer patients were retrospectively selected. PET/CT images were registered with planning CT scans using commercially available software. Radiation oncologists defin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 2015