Impedance Cardiography Accurately

نویسنده

  • Paul T. Pianosi
چکیده

Objectives: After validation of impedance cardiography (ICG) in healthy children, this same device was tested in children with cystic fibrosis (CF) to validate its capability of measuring cardiac output (Q) in this population. Design: Comparative study of ICG vs the indirect Fick (C02) method. Setting: Tertiary care children's teaching hospital. Patients: Twenty-one CF children with mean FEVX of 77±21% predicted. Measurements: ICG results were compared with C02 rebreathing (RB) measurements of Q with sampling of capillary blood gases at two levels of exercise (0.5 and 1.5 W/kg). ICG measurements

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior-posterior impedance cardiography: a new approach to accurate, non-invasive monitoring of cardiac function.

The conventional impedance cardiogram is a record of pulsatile changes in the electrical impedance of the chest with each heartbeat. The signal seems intuitively related to cardiac stroke volume. However doubts persist about the validity of stroke volume measurements based on electrical impedance. This paper presents a new electrical axis for impedance cardiography that is perpendicular to the ...

متن کامل

Large-scale ensemble averaging of ambulatory impedance cardiograms.

Impedance cardiography has been used increasingly to measure human physiological responses to emotional and mentally engaging stimuli. The validity of large-scale ensemble averaging of ambulatory impedance cardiograms was evaluated for preejection period (PEP), interbeat interval, and dZ/dt(min) amplitude. We tested whether the average of "classical" 60-sec ensemble averages across periods with...

متن کامل

Utility of impedance cardiography to improve physician estimation of hemodynamic parameters in the emergency department.

Emergency physicians must often make assessments of complex hemodynamic parameters. To assess the utility of impedance cardiography (ICG) in the emergency department, the authors examined treating physicians' abilities to assess stroke volume (SV), cardiac output (CO), and systemic vascular resistance (SVR) by comparing the clinicians' estimates of these values to ICG measurements. Treating phy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007