Data acquisition card for fluctuation correlation spectroscopy allowing full access to the detected photon sequence
نویسندگان
چکیده
Typically, fluctuation correlation spectroscopy ~FCS! data acquisition cards measure the number of photon events per time interval ~i.e., bin!—time mode. Commercial FCS cards combine the bins through hardware in order to calculate the autocorrelation function. Such a design therefore does not yield the time resolved photon sequence, but only the autocorrelation of that sequence. A different acquisition method which measures the number of time intervals between photon events has been implemented—photon mode. This method takes advantage of the fact that in FCS the rate of photon counts is much less than the frequency of the clock that is used to determine the temporal location of the photons. By using this new mode of data acquisition, the current card design allows for 25 ns time resolution. The data acquisition card can operate in both time and photon mode and yields the time resolved sequence of photon arrivals in both cases. Therefore, the data is available for analysis by any method~s!, such as but not limited to, autocorrelation, photon counting histogram, and higher order autocorrelation. © 2000 American Institute of Physics. @S0034-6748~00!05202-3#
منابع مشابه
Time-to-Digital Converter card for multichannel time-resolved Single-Photon Counting applications
We present a high performance Time-to-Digital Converter (TDC) card that provides 10 ps timing resolution and 20 ps (rms) timing precision with a programmable full-scale-range from 160 ns to 10 μs. Differential Non-Linearity (DNL) is better than 1.3% LSB (rms) and Integral Non-Linearity (INL) is 5 ps rms. Thanks to the low power consumption (400 mW) and the compact size (78 mm x 28 mm x 10 mm), ...
متن کاملA new method for acquisition and analysis of single unit recording data
Single unit recording has been used as a well-known technique to study the electrical behavior of neurons. In this respect, the classical methods are rather expensive. In this study a simple and inexpensive method for single unit recording studies has been introduced. Computer sound card was used for data acquisition. Neural responses were saved via simple sound applicable packages and then ana...
متن کاملThe production of lexical categories (VP) and functional categories (copula) at the initial stage of child L2 acquisition
This is a longitudinal case study of two Farsi-speaking children learning English: ‘Bernard’ and ‘Melissa’, who were 7;4 and 8;4 at the start of data collection. The research deals with the initial state and further development in the child second language (L2) acquisition of syntax regarding the presence or absence of copula as a functional category, as well as the role and degree of L1 influe...
متن کاملFast calculation of fluorescence correlation data with asynchronous time-correlated single-photon counting.
Fluorescence correlation spectroscopy (FCS) is a powerful spectroscopic technique for studying samples at dilute fluorophore concentrations down to single molecules. The standard way of data acquisition, at such low concentrations, is an asynchronous photon counting mode that generates data only when a photon is detected. A significant problem is how to efficiently convert such asynchronously r...
متن کاملPaxillin Dynamics Measured during Adhesion Assembly and Disassembly by Correlation Spectroscopy
Paxillin is an adaptor molecule involved in the assembly of focal adhesions. Using different fluorescence fluctuation approaches, we established that paxillin-EGFP is dynamic on many timescales within the cell, ranging from milliseconds to seconds. In the cytoplasmic regions, far from adhesions, paxillin is uniformly distributed and freely diffusing as a monomer, as determined by single-point f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000