Chest wall kinematic determinants of diaphragm length by optoelectronic plethysmography and ultrasonography.
نویسندگان
چکیده
To estimate diaphragm fiber length from thoracoabdominal configuration, we measured axial motion of the right-sided area of apposition by ultrasonography and volumes displaced by chest wall compartments [pulmonary, abdominal rib cage, and abdomen (Vab)] by optoelectronic plethysmography in four normal men during quiet breathing and incremental exercise without and with expiratory flow limitation. Points at the cephalic area of apposition border were digitized from echo images and mapped into three-dimensional space, and the axial distance from the xyphoidal transverse plane (D(ap)) was measured simultaneously with the volumes. Linear regression analysis between changes (Delta) in D(ap) and the measured volume changes under all conditions showed that 1) DeltaD(ap) was linearly related more to DeltaVab than to changes in pulmonary and abdominal rib cage volumes; and 2) this was highly repeatable between measures. Multiple stepwise regression analysis showed that DeltaVab accounted for 89-96% of the variability of DeltaD(ap), whereas the rib cage compartments added <1%. We conclude that, under conditions of quiet breathing and exercise, with and without expiratory flow limitation, instantaneous DeltaD(ap) can be estimated from DeltaVab.
منابع مشابه
Chest wall mechanics before and after diaphragm plication
BACKGROUND Following diaphragmatic plication for unilateral paralysis, the effect on global chest wall function are unknown. Our hypothesis was that chest wall function would improve in both sides of the chest after plication of the paralysed side. CASE PRESENTATION Using Optoelectronic Plethysmography, total and regional chest wall volumes were measured in one patient before and after left d...
متن کاملDevelopment Of A Bio-Inspired Mechatronic Chest Wall Simulator For Evaluating The Performances Of Opto-Electronic Plethysmography
Instrumented gait analysis based on optoelectronic systems is an expensive technique used to objectively measure the human movement features and it is generally considered as the gold standard. Opto-electronic plethysmography (OEP) is a particular motion analysis system able to: (i) determine chest wall kinematic via the evaluation of marker displacements placed on the thorax and (ii) compute r...
متن کاملRespiratory muscle dynamics and control during exercise with externally imposed expiratory flow limitation.
To determine how decreasing velocity of shortening (U) of expiratory muscles affects breathing during exercise, six normal men performed incremental exercise with externally imposed expiratory flow limitation (EFLe) at approximately 1 l/s. We measured volumes of chest wall, lung- and diaphragm-apposed rib cage (Vrc,p and Vrc,a, respectively), and abdomen (Vab) by optoelectronic plethysmography;...
متن کاملThe effect of posture on asynchronous chest wall movement in COPD.
Chronic obstructive pulmonary disease (COPD) patients often show asynchronous movement of the lower rib cage during spontaneous quiet breathing and exercise. We speculated that varying body position from seated to supine would influence rib cage asynchrony by changing the configuration of the respiratory muscles. Twenty-three severe COPD patients (forced expiratory volume in 1 s = 32.5 ± 7.0% p...
متن کاملChest wall kinematics and respiratory muscle action in ankylosing spondylitis patients.
No direct measurements of the pressures produced by the ribcage muscles, the diaphragm and the abdominal muscles during hyperventilation have been reported in patients with ankylosing spondylitis. Based on recent evidence indicating that abdominal muscles are important contributors to stimulation of ventilation, it was hypothesised that, in ankylosing spondylitis patients with limited ribcage e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 94 2 شماره
صفحات -
تاریخ انتشار 2003