Adjustment of ventilation windows for optimal number of air changes of a smelter pot room using mathematical optimization
نویسندگان
چکیده
1. Abstract The only large-scale cost-effective way to exhaust contaminated air from the furnace pot room of an industrial plant is through natural ventilation. The effectiveness of the ventilation depends, amongst others, on the openings of the windows through which the air is allowed to enter and exit the workshop. The ventilation is also directly influenced by the prevailing weather outside the building. An appropriate measure that characterises the ventilation within the workshop is the number of air changes per hour and ideally it should be close to a prescribed value for all weather conditions. This requirement can be met by the appropriate adjustment of the opening angles of the inlet and outlet window slats. This paper reports on the feasibility of using mathematical optimisation to determine the ideal window slat angles for different prevailing wind conditions. The proposed optimisation methodology employs computational fluid dynamics software (FLUENT), coupled to a computationally economic optimisation algorithm (Dynamic-Q), to determine the optimal slat angles. Results of the successful application of the proposed optimisation procedure to an example problem of a large-scale aluminium smelter pot room are presented.
منابع مشابه
تاثیر تهویه بر تراکم آلایندههای بیولوژیک هوا در یک اتاق بیمار مسلول
Background: Ventilation plays a crucial role in reducing the number of air transmitted pathogens in isolated rooms. Determination of the suitable type of ventilation system and the proper ventilating rate has always been a challenge. Patients’ bed arrangement and the location of the staff are also expected to influence the occupational exposure of the staffs’ to harmful airborne particles. The...
متن کاملتعیین اثر بخشی حالات مختلف سامانه تهویه بر کاهش میزان مواجهه شغلی کارکنان درمانی با بیوآئروسل ها
Background & Objectives : Hospital indoor air contains a wide range of airborne pathogenic bioaerosols which have a significant impact on health care staff’ health and welfare. The aim of this study was to assess the effects of ventilation system types on occupational exposure of the health care staffs to airborne bioaerosols in the isolation room based on the patient bed arrangements and...
متن کاملOptimization of Finned-Tube Heat Exchanger with Minimizing the Entropy Production rate
A compact fin-tube heat exchanger is used to transfer current fluid heat inside the tubes into the air outside. In this study, entropy production and optimized Reynolds number for finned-tube heat exchangers based on the minimum entropy production have been investigated. As a result, the total entropy of compact heat exchangers, which is the summation of the production rate of fluid entropy ins...
متن کاملComparison of work environment air quality and application of Geostatistic technique in the Spatial distribution of PM2.5 and PM10 in a number of industrial workshops
Introduction: Air quality in industrial workshops is affected by various harmful chemical agents. purpose of this study was to compare of work environment air quality in a number of industrial workshops based on the mass concentration and number of suspended particles in air and application of Kriging geostatistical method in industries. Material and Method: This observational study was ca...
متن کاملSimulation of air input and output port locations for reaching to the best ventilation condition for a room
This article has no abstract.
متن کامل