Elimination of biofilm and microbial contamination reservoirs in hospital washbasin U-bends by automated cleaning and disinfection with electrochemically activated solutions.
نویسندگان
چکیده
BACKGROUND Washbasin U-bends are reservoirs of microbial contamination in healthcare environments. U-Bends are constantly full of water and harbour microbial biofilm. AIM To develop an effective automated cleaning and disinfection system for U-bends using two solutions generated by electrochemical activation of brine including the disinfectant anolyte (predominantly hypochlorous acid) and catholyte (predominantly sodium hydroxide) with detergent properties. METHODS Initially three washbasin U-bends were manually filled with catholyte followed by anolyte for 5min each once weekly for five weeks. A programmable system was then developed with one washbasin that automated this process. This U-bend had three cycles of 5min catholyte followed by 5min anolyte treatment per week for three months. Quantitative bacterial counts from treated and control U-bends were determined on blood agar (CBA), R2A, PAS, and PA agars following automated treatment and on CBA and R2A following manual treatment. FINDINGS The average bacterial density from untreated U-bends throughout the study was >1×10(5) cfu/swab on all media with Pseudomonas aeruginosa accounting for ∼50% of counts. Manual U-bend electrochemically activated (ECA) solution treatment reduced counts significantly (<100cfu/swab) (P<0.01 for CBA; P<0.005 for R2A). Similarly, counts from the automated ECA-treatment U-bend were significantly reduced with average counts for 35 cycles on CBA, R2A, PAS, and PA of 2.1±4.5 (P<0.0001), 13.1±30.1 (P<0.05), 0.7±2.8 (P<0.001), and 0 (P<0.05) cfu/swab, respectively. P. aeruginosa was eliminated from all treated U-bends. CONCLUSION Automated ECA treatment of washbasin U-bends consistently minimizes microbial contamination.
منابع مشابه
Effect of Low Energy Surface Vibration on the Anti-adhesive Properties of Multipurpose Solutions
Contact lenses are a successful form of vision correction. But their use has been associated with an increased risk of microbial keratitis (MK), contact lens related acute red eye (CLARE) as well as contact lens peripheral ulcer (CLPU) (Eltis, 2011). One of the main problems associated with contact lenses is microbial contamination of the lens surface. Microbial contamination further leads to t...
متن کاملComparison of Health Status of Medical Equipment Levels and Pseudo-Homogeneous Environmental Levels in One of Ardebil Hospitals by Observation Method (ICNA) and Microbial (ACC) During Autumn 2017
Background and objectives: The transmission of infection from the equipment and the environment to patients is widely carried out through contact. The aim of this study was to determine the health status of medical equipment and pseudo-homogeneous environmental levels in hospitals in Ardebil, in observational and microbiological hospitals in year 1396. Methods: in this descriptive cross-section...
متن کاملارزیابی خطر انتقال عفونت های بیمارستانی در بخش مراقبت های ویژه بیمارستان بهشتی کاشان درسال 1390
Background: Microbial contaminations occurred in “Intensive Care Unit” (ICU) is the substantial cause of infection transmission within hospitals. The infectious organisms can be transmitted mainly through contact with the surface of instruments. Indicating the contaminated sources is the primary step during the infection control program. This study aimed to evaluate the risk of cross infection ...
متن کاملSurface-attached cells, biofilms and biocide susceptibility: implications for hospital cleaning and disinfection.
Microbes tend to attach to available surfaces and readily form biofilms, which is problematic in healthcare settings. Biofilms are traditionally associated with wet or damp surfaces such as indwelling medical devices and tubing on medical equipment. However, microbes can survive for extended periods in a desiccated state on dry hospital surfaces, and biofilms have recently been discovered on dr...
متن کاملEfficacy of Biofilm Removal From Hemodialysis Piping
BACKGROUND Central dialysate fluid delivery systems (CDDS) are used by dialysis centers in Japan, and although these systems are effective at delivering dialysate, they have a complex piping network with numerous sites where contamination can develop. In Japan, cleaning disinfectants have been clinically evaluated based on endotoxin levels and bacterial counts, but there have been no published ...