Evaluation of the Beckman creatinine analyzer.
نویسندگان
چکیده
We compared results obtained with the Beckman Creatinine Analyzer (Beckman Instruments, Inc.) to those with the GEMSAEC Centrifugal Analyzer (Electro-Nucleonics, Inc.) and with a manual method for determination of creatinine in serum and urine. Linearity, stability, recovery, and precision were evaluated. Interference from bilirubin, protein, lipemia, uric acid, and hemolysis is negligible, but acetone and acetoacetate can interfere.
منابع مشابه
Comparison of plasma creatinine determined with the Greiner Selective Analyser GSA II and the glomerular filtration rate.
1. Reference values for the plasma creatinine were established using the alkaline picrate method with the Greiner Selective Analyzer GSA II in relation to the Cr 51-EDTA Clearance. Individuals with normal GFR between 93 to 159 ml/min/1.73 m2 had creatinine values in men (n = 65) from 53.7 to 119.5 mumol/l (0.61 to 1.35 mg/100 ml) and in women (n = 59) from 37.7 to 107 mumol/l (0.42 to 121 mg/10...
متن کاملEvaluation of a new multichannel analyzer, "Astra-8".
We evaluated a new multiple-channel chemistry analyzer, the Beckman "Astra-8," which is controlled by a microprocessor with 52K bytes of memory. The instrument we tested performed the following tests: Na, K, CO2, chloride, urea nitrogen, glucose, and creatinine. We compared the Astra-8 to a continuous-flow (SMA 6/60) and a discrete (Du Pont aca, urea nitrogen only) analyzer. The Astra-8 demonst...
متن کاملAnalytical Evaluation of the Clinical Chemistry Analyzer AU 480 Beckman Coulter
Background: Method verification is a one-time process to determine performance characteristics before a test system is utilized for patient testing. Objective: To evaluate the analytical performance of five analytes-glucose (glu), cholesterol (chol), creatinine (crea), aspartate aminotransferase, (AST) and alanine aminotransferase (ALT) on AU 480 Beckman Coulter clinical chemistry analyzer. Met...
متن کاملKinetic serum creatinine assays. II. A critical evaluation and review.
We have evaluated the Technicon AutoAnalyzer method, the Beckman Creatinine Analyzer II, DuPont aca, Electro-Nucleonics GEMSAEC, and Instrumentation Laboratory Model 916 kinetic methods for determination of serum creatinine. These methods, which involve the Jaffé reaction, all showed a statistically significant proportional error relative to an ion-exchange pretreatment method for creatinine in...
متن کاملLaboratory evaluation of the Beckman Synchron CX3 clinical chemistry analyzer.
In this evaluation of the Beckman Synchron CX3, the multi-analyte clinical chemistry analyzer exhibited high precision, good linearity, and no carryover for each of the eight analytes measured. Results obtained correlated well with those produced by our routine instrumentation (Beckman Astra, Varian atomic absorption spectrophotometer). The instrument can process up to 75 samples per hour (600 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 6 شماره
صفحات -
تاریخ انتشار 1979