Does the dynamic sling effect of the Latarjet procedure improve shoulder stability? A biomechanical evaluation.

نویسندگان

  • Joshua W Giles
  • Harm W Boons
  • Ilia Elkinson
  • Kenneth J Faber
  • Louis M Ferreira
  • James A Johnson
  • George S Athwal
چکیده

INTRODUCTION Glenohumeral instability with glenoid bone loss is commonly treated with the Latarjet procedure. The procedure involves transfer of the coracoid and conjoint tendon, which is thought to provide a stabilizing sling effect; however, its significance is unknown. This study evaluated the effects of the Latarjet procedure, with and without conjoint tendon loading, on shoulder stability and range of motion (ROM). MATERIALS AND METHODS A custom simulator was used to evaluate anterior shoulder stability and ROM in 8 cadaveric shoulders. Testing conditions included intact, 30% glenoid defect, and Latarjet with and without conjoint loading. Unloaded and 10-N loaded states were tested in adduction and 90° abduction. Outcome variables included dislocation, stiffness (neutral and 60° external rotation), and internal-external rotational ROM. RESULTS All 30% defects dislocated in abduction external rotation. The loaded Latarjet prevented dislocation in all specimens, whereas the unloaded Latarjet stabilized 6 of 8 specimens. In abduction external rotation, there were no significant differences in stiffness between loaded and unloaded transfers (P = .176). In adduction, there were no significant differences between the intact and the loaded Latarjet (P ≥ .228); however, in neutral rotation, the unloaded Latarjet (P = .015) and the 30% defects (P = .011) were significantly less stiff. Rotational ROM in abduction was significantly reduced with the loaded Latarjet (P = .014) compared with unloaded Latarjet, and no differences were found in adduction. CONCLUSIONS These findings indicate that glenohumeral stability is improved, but not fully restored to intact, with conjoint tendon loading. The results support the existence of the sling effect and its importance in augmenting stability provided by the transferred coracoid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new subscapular sling operation to stabilize the shoulder. A cadaver study

INTRODUCTION A new arthroscopic shoulder stabilisation procedure is proposed, which for some patients could be an alternative to the arthroscopic Latarjet procedure. METHODS The objective was to stabilize the shoulder by making a sling around the subscapularis tendon, using a hamstring graft and enhancing the anterior rim of the glenoid with the same graft. The anatomical feasibility of the s...

متن کامل

What is the Stabilizing Mechanism of the Latarjet Procedure?

INTRODUCTION: The Latarjet procedure is one of the common procedures with excellent clinical results for treating patients with anterior instability of the shoulder. Recently, it has also been used as a bone-grafting procedure in patients with a large glenoid defect. To date, “sling effect of the subscapularis muscle” and “bone block effect of the coracoid process” have been considered as the m...

متن کامل

Neurovascular Compression After the Latarjet Procedure.

The Latarjet procedure is an established and effective option for the treatment of recurrent anterior shoulder instability. Symptomatic compression of the vasculature around the shoulder and adjacent brachial plexus is uncommon and may be difficult to diagnose and treat. The purpose of this report is to describe a patient with neurovascular compression of the axillary artery and brachial plexus...

متن کامل

Arthroscopic Transfer of the Conjoined Tendon–Coracoid Tip Complex for Anterior Shoulder Instability

In the treatment of anterior shoulder instability, there are various conditions in which a sling effect is needed to enhance anterior stability. The traditional Bristow-Latarjet procedure provides a sling effect but destroys or does not purposely protect the coracoacromial (CA) arch, which may result in superior instability. To preserve the CA arch and create a sling to enhance the anterior-inf...

متن کامل

Biomechanical Comparison of the Latarjet Procedure with and without Capsular Repair.

BACKGROUND The purpose of this study was to determine if capsular repair used in conjunction with the Latarjet procedure results in significant alterations in glenohumeral rotational range of motion and translation. METHODS Glenohumeral rotational range of motion and translation were measured in eight cadaveric shoulders in 90° of abduction in both the scapular and coronal planes under the fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 22 6  شماره 

صفحات  -