Morphological analysis of interbody fusion following posterior lumbar interbody fusion with cages using computed tomography

نویسندگان

  • Dong Kwang Seo
  • Myeong Jong Kim
  • Sung Woo Roh
  • Sang Ryong Jeon
چکیده

Posterior lumbar interbody fusion (PLIF) using cages in conjunction with pedicle screw fixation is considered the gold standard for surgical treatment of degenerative lumbar spine disorders due to its biomechanical stability and high fusion rate. However, research regarding patterns of fusion in the interbody space during the early postoperative period is lacking.Sixty consecutive patients were recruited from May 2013 to June 2015. All patients underwent PLIF using 2 titanium cages filled with local bone chips from decompressed lamina and facet bone in conjunction with pedicle screw fixation. Computed tomography scans were obtained 3 to 6 months following surgery in order to evaluate the partial fusion state. Computed tomography (CT) classification of fusion morphology was divided into 8 groups and then into compartments according to fusion space, and the rate of fusion for each was calculated. Further follow-up was conducted to confirm fusion state and assess outcomes.The most frequent pattern of interbody fusion was bilateral intra-cage fusion with unilateral lateral bridging of extra-cage areas (N = 36, 43.4%); the least frequent was interspace bridging of the 2 cages alone (N = 0, 0%). The fusion rate for the intra-cage area (Compartment 1) reached 100%. However, the fusion in the lateral space outside of cages (Compartment 2) was not satisfactory, though reasonable (72.3%). All patients were confirmed as achieving adequate fusion at the final follow-up, with improved clinical outcomes.Widening of the contact area between the vertebral body and cages is recommended to promote increased interbody fusion during the early postoperative period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusion assessment of posterior lumbar interbody fusion using radiolucent cages: X-ray films and helical computed tomography scans compared with surgical exploration of fusion.

BACKGROUND Plain radiographic assessment of posterolateral fusion has been reported as accurate in only two thirds of patients who were found to be healed at surgical exploration. Plain radiographic techniques for fusion assessment of interbody fusion with radiolucent cages are reported to be accurate. A helical computed tomography (CT) scan shows a high sensitivity for pseudarthrosis compared ...

متن کامل

Report on two failed posterior lumbar interbody fusions

Despite X-ray and computed tomography signs of osseous stability after posterior lumbar interbody fusion (PLIF) procedures, the examination of two patients after 28 and 24 months respectively, revealed that the cages were wandering and consolidation had not taken place. Revision surgery was required in both cases. Introduction Fusion surgery in the region of the lumbar spine has become standard...

متن کامل

Is one cage enough in posterior lumbar interbody fusion: a comparison of unilateral single cage interbody fusion to bilateral cages.

Posterior lumbar interbody fusion (PLIF), as recommended with bilateral lumbar interbody cages and pedicle screw fixation, has increased the successful fusion rate to nearly 100%. Presently, a unilateral approach to the disc space with a variant of PLIF, the trans-foraminal interbody fusion is often used. There are few clinical studies of unilateral interbody fusion. The clinical and fusion res...

متن کامل

Clinical and Radiological Results of Microsurgical Posterior Lumbar Interbody Fusion and Decompression without Posterior Instrumentation for Lateral Recess Stenosis

STUDY DESIGN A single-center, retrospective patient review of clinical and radiological outcomes of microsurgical posterior lumbar interbody fusion and decompression, without posterior instrumentation, for the treatment of lateral recess stenosis. PURPOSE This study documented the clinical and radiological results of microsurgical posterior lumbar interbody fusion and decompression of the lat...

متن کامل

Can Posterior Lumbar Instrumentation and Fusion Be Overpowered by Anterior Lumbar Fusion With Hyperlordotic Cages? A Cadaveric Study

STUDY DESIGN Technical report on cadavers. OBJECTIVE To evaluate preliminary feasibility and safety of lumbar sagittal alignment correction with anterior hyperlordotic cages used to overpower previous posterior spinal instrumentation. METHODS Hyperlordotic 30° anterior lumbar interbody fusion (ALIF) cages were inserted in collapsed L5-S1 disc space of 2 cadavers to overpower prior posterior...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017