Application of holographic display in radiotherapy treatment planning II: a multi‐institutional study
نویسندگان
چکیده
We hypothesized that use of a true 3D display providing easy visualization of patient anatomy and dose distribution would lead to the production of better quality radiation therapy treatment plans. We report on a randomized prospective multi-institutional study to evaluate a novel 3D display for treatment planning.The Perspecta Spatial 3D System produces 360 degrees holograms by projecting crosssectional images on a diffuser screen rotating at 900 rpm. Specially-developed software allows bi-directional transfer of image and dose data between Perspecta and the Pinnacle planning system.Thirty-three patients previously treated at three institutions were included in this IRB-approved study. Patient data were de-identified, randomized, and assigned to different planners. A physician at each institution reviewed the cases and established planning objectives. Two treatment plans were then produced for each patient, one based on the Pinnacle system alone and another in conjunction with Perspecta. Plan quality was then evaluated by the same physicians who established the planning objectives. All plans were viewable on both Perspecta and Pinnacle for review. Reviewing physicians were blinded to the planning device used. Data from a 13-patient pilot study were also included in the analysis.Perspecta plans were considered better in 28 patients (61%), Pinnacle in 14 patients (30%), and both were equivalent in 4 patients. The use of non-coplanar beams was more common with Perspecta plans (82% vs. 27%). The mean target dose differed by less than 2% between rival plans. Perspecta plans were somewhat more likely to have the hot spot located inside the target (43% vs. 33%). Conversely, 30% of the Pinnacle plans had the hot spot outside the target compared with 18% for Perspecta plans. About 57% of normal organs received less dose from Perspecta plans. No statistically significant association was found between plan preference and planning institution or planner.The study found that use of the holographic display leads to radiotherapy plans preferred in a majority of cases over those developed with 2D displays. These data indicate that continued development of this technology for clinical implementation is warranted.
منابع مشابه
Multi-institutional comparison of treatment planning using stereotactic ablative body radiotherapy for hepatocellular carcinoma – benchmark for a prospective multi-institutional study
INTRODUCTION Several single institution phase I and phase II trials of stereotactic ablative body radiotherapy (SABR) for liver tumors have reported promising results and high local control rates of over 90%. However, there are wide variations in dose and fractionation due to different prescription policies and treatment methods across SABR series that have been published to date.This study aim...
متن کاملA MULTI-OBJECTIVE EVOLUTIONARY ALGORITHM USING DECOMPOSITION (MOEA/D) AND ITS APPLICATION IN MULTIPURPOSE MULTI-RESERVOIR OPERATIONS
This paper presents a Multi-Objective Evolutionary Algorithm based on Decomposition (MOEA/D) for the optimal operation of a complex multipurpose and multi-reservoir system. Firstly, MOEA/D decomposes a multi-objective optimization problem into a number of scalar optimization sub-problems and optimizes them simultaneously. It uses information of its several neighboring sub-problems for optimizin...
متن کاملSkin in vivo Dosimetry in Radiotherapy
Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...
متن کاملThe Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose
Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...
متن کاملInvestigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy
Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...
متن کامل