Comparison of internal fit between implant abutments and cast metal crowns vs laser-sintered crowns.

نویسندگان

  • Mehmet Ali Kiliçarslan
  • Pelin Özkan
  • Bülent Uludag
  • Emre Mumcu
چکیده

AIM A common problem related to cemented single crowns is the internal misfit, which may cause inadequate retention, especially when seated on the implant abutment. The aim of this study was to compare the internal fit of Co-Cr crowns using a traditional lost-wax casting technique from laser-sintered Co-Cr alloy crowns. MATERIALS AND METHODS Twelve metallic crowns per each technique were fabricated. The effect of the thickness of cement, originated internal gap was evaluated. Crowns were cemented on the implant abutments with resin cement, and the internal fit of crowns was measured at five areas with an optical microscope. The data were analyzed, and the means were compared with a t-test (p<0.05). RESULTS The internal gap width measurements for the laser-sintered group (min. 52.19 ± 11.61 μm and max. 140.01 ± 31.84 μm) indicated the presence of a significantly closed internal gap compared to the crowns obtained through the lost wax method (min. 65.50 ± 9.54 μm and max. 313.46 ± 48.12 μm). CONCLUSION The fit of the metal crown likely varies with the fabrication technique. The use of techniques that enable the adjustment of crown parameters, such as the laser sintering technique, maintains the desired fit between casting and implant abutments. CLINICAL SIGNIFICANCE This study investigated which technique affects the internal fit of cemented implant-supported crowns, comparing the use of lost wax casting and laser-sintered metal dental alloys. The results of this study indicate that the use of laser-sintered crowns can improve for crown accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CAD/CAM to fabricate ceramic implant abutments and crowns: a preliminary in vitro study.

BACKGROUND This study evaluated the feasibility of fabricating implant abutments and crowns from pre-sintered feldspathic porcelain blocks using the chair-side CAD/CAM, CEREC3D((R)) system. METHODS Thirty-two implant analogues were divided into two groups. In the control group, prefabricated machined anatomical titanium (Ti) abutments were screw-retained to the analogues. In the test group, m...

متن کامل

Marginal Fit Metal-Ceramic and In-Ceram Single Crown Cement retained in Implant-supported Abutments.

INTRODUCTION This study evaluated the cervical fit of cemented metal-ceramic and In-Ceram implant-supported crowns, before and after the cementing procedure. MATERIALS AND METHODS Twenty crowns cemented on implant abutments are divided into two groups (n = 10): Group 1 -cemented metal-ceramic crowns and group 2 - cemented In-Ceram crowns. The marginal adaptations before and after cementation ...

متن کامل

Effect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crowns

The passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 1...

متن کامل

The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...

متن کامل

Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments.

This in vitro study quantified the marginal discrepancy of the implant-to-prosthetic-crown interface on nonsubmerged dental implants restored with either a cemented or a screw-retained approach. Metal-ceramic crowns were fabricated for 20 ITI 4.1 x 10 mm solid-screw titanium implants. Ten implants received octa abutments and screw-retained crowns fabricated on premachined gold cylinders. The re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2014