Comparison of the Amplicor HIV-1 monitor test and the nucleic acid sequence-based amplification assay for quantitation of human immunodeficiency virus RNA in plasma, serum, and plasma subjected to freeze-thaw cycles.

نویسندگان

  • B P Griffith
  • M O Rigsby
  • R B Garner
  • M M Gordon
  • T M Chacko
چکیده

The Amplicor HIV-1 Monitor test was compared to the nucleic acid sequence-based amplification (Nasba) assay system for the quantitation of human immunodeficiency virus (HIV) RNA in three different types of clinical samples: plasma, serum, and plasma subjected to freeze-and-thaw cycles. Each assay detected HIV RNA in the same 73 (90%) of 81 samples tested, and the quantitative results obtained with the two assays were significantly correlated. Both assays detected higher RNA levels in patients with CD4+ cell counts lower than 200 cells/mm3 than in patients with CD4+ cell counts higher than 200 cells/mm3. In addition, RNA levels in plasma higher than 5 logs predicted higher numbers of clinical events than did RNA levels in plasma lower than 5 logs. Quantitation of HIV RNA in paired plasma and serum samples showed lower HIV RNA content in serum than in the paired plasma sample, with mean differences between HIV RNA contents of plasma and serum of 0.54 and 0.28 log RNA copy/ml by the Nasba assay and the Amplicor HIV-1 Monitor assay, respectively. No significant loss of HIV RNA was detected with either assay in plasma samples subjected to multiple freeze-and-thaw cycles. These studies demonstrate that the Nasba and Amplicor assays perform similarly with plasma and serum samples. Further, the results indicate that freeze-and-thaw cycles do not result in significant loss of detectable HIV RNA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simple and Rapid Method for the Detection of HIV-1/HCV in Co-Infected Patients

  Background: Due to some limitations of serological methods in diagnosis of patients infected with HIV-1 (human immunodeficiency virus) and HCV (hepatitis C virus), it is profoundly important to use molecular methods for the detecting of these infectious agents. However, the most significant problems are the exorbitant cost of these methods and the need of a thermocycler which is an expensive...

متن کامل

Comparison of the QUANTIPLEX HIV-1 RNA 2.0 assay with the AMPLICOR HIV-1 MONITOR 1.0 assay for quantitation of levels of human immunodeficiency virus type 1 RNA in plasma of patients receiving stavudine-didanosine combination therapy.

We compared the QUANTIPLEX HIV-1 RNA 2.0 assay with the AMPLICOR HIV-1 MONITOR 1.0 assay for quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in plasma in the Stadi trail, which evaluated a stavudine plus didanosine combination therapy in 52 patients. HIV-1 RNA baseline values measured with AMPLICOR HIV-1 MONITOR 1.0 were significantly higher than those measured with QUANTIPLEX H...

متن کامل

Multicenter evaluation of the performance characteristics of the NucliSens HIV-1 QT assay used for quantitation of human immunodeficiency virus type 1 RNA.

The analytical performance of the NucliSens HIV-1 QT assay, a highly sensitive test based on nucleic acid sequence-based amplification technology, was evaluated in a multicenter trial. Assay specificity was evaluated with 502 plasma (EDTA) specimens from human immunodeficiency virus type 1 (HIV-1)-seronegative volunteer donors. No HIV-1 RNA was reported in any of the donor specimens. Analytical...

متن کامل

Ultrasensitive reverse transcription-PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma.

With the recent introduction of combination therapy, human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma have been dramatically reduced, frequently to below the limit of quantitation (400 copies/ml of plasma) of the AMPLICOR HIV-1 MONITOR Test (Roche Diagnostic Systems). To achieve enhanced sensitivity of the AMPLICOR HIV-1 MONITOR Test, a modified specimen preparation procedure th...

متن کامل

Use of active surveillance cultures in intensive care units.

3. Katsoulidou A, Petrodaskalaki M, Sypsa V, et al. Evaluation of the clinical sensitivity for the quantitation of human immunodeficiency virus type 1 RNA in plasma: comparison of the new Cobas TaqMan HIV-1 with three current HIV-RNA assays–LCx HIV RNA quantitative, Versant HIV-1 RNA 3.0 (bDNA) and Cobas Amplicor HIV-1 Monitor v1.5. J Virol Methods 2006; 131:168–74. 4. Damond F, Roquebert B, Be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 1997