Contribution to the Nsac Long-range Plan the Future of Gamma-ray Spectroscopy: Greta, the Gamma-ray Energy Tracking Array
ثبت نشده
چکیده
منابع مشابه
An investigation of using hump in the Cherenkov photon lateral distribution for Gamma-Hadron separation
Simulation of gamma and hadron showers in the energy range 100GeV- 25TeV has been carried out. For a big ideal Cherenkov light array, characteristics of lateral distribution of Cherenkov photon density have been studied. Results from this ideal detector are compared with those simulated for a real TUNKA- like array to investigate experimental potential of using existence of a hump in lateral di...
متن کاملTransition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations
In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...
متن کاملA STUDY OF GAMMA RAY EXPOSURE BUILDUP FACTORS IN STRATIFIED SHIELDS FOR POINT ISOTROPIC SOURCES, INCLUDING THE EFFECTS OF INCOHERENT AND COHERENT SCATTERING
The effects of including incoherent (bound-electron) and coherent (Rayleigh) scattering in exposure buildup factor calculations for point isotropic gamma ray sources, penetrating a two-layer water-lead shield have been investigated in the gamma ray energy (E?) range of 40 keV to 3 MeV. Incoherent scattering decreases the values of these factors in both layers up to E? ~ 200 keV and the effect i...
متن کاملWater Absorption of Chitosan, Collagen and Chitosan/Collagen Blend Membranes Exposed to Gamma-ray Irradiation
TThis study investigated the water absorption of chitosan, collagen, and chitosan/collagen blend membranes exposed to gamma-ray irradiation. These membranes were produced via the solvent evaporation method. All membranes then underwent irradiation at 15 or 25 kGy gamma-ray doses, while membranes without irradiation were used as controls. After immersing the membranes in distilled water for up t...
متن کاملDetermination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods
High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...
متن کامل