Is Unilateral Implant or Autologous Breast Reconstruction Better in Obtaining Breast Symmetry?

نویسندگان

  • Oriana Cohen
  • Kevin Small
  • Christina Lee
  • Oriana Petruolo
  • Nolan Karp
  • Mihye Choi
چکیده

Unilateral breast reconstruction poses a special set of challenges to the reconstructive breast surgeon compared to bilateral reconstructions. No studies to date provide an objective comparison between autologous and implant based reconstructions in matching the contralateral breast. This study compares the quantitative postoperative results between unilateral implant and autologous flap reconstructions in matching the native breast in shape, size, and projection using three-dimensional (3D) imaging. Sixty-four patients who underwent unilateral mastectomy with tissue expander (TE)-implant (n = 34) or autologous microvascular free transverse rectus abdominus myocutaneous (TRAM; n = 18) or deep inferior epigastric artery perforator (DIEP; n = 12) flap (n = 30) reconstruction from 2007 to 2010 were analyzed. Key patient demographics and risk factors were collected. Using 3D scans of patients obtained during pre and postoperative visits including over 1 year follow-ups for both groups, 3D models were constructed and analyzed for total breast volume, anterior-posterior projection from the chest wall, and 3D comparison. No significant differences in mean age, body mass index, or total number of reconstructive surgeries were observed between the two groups (TE-implant: 52.2 ± 10, 23.9 ± 3.7, 3 ± 0.9; autologous: 50.7 ± 9.4, 25.4 ± 3.9, 2.9 ± 1.3; p > 0.05). The total volume difference between the reconstructed and contralateral breasts in the TE-implant group was insignificant: 27.1 ± 22.2 cc, similar to the autologous group: 29.5 ± 24.7 cc, as was the variance of breast volume from the mean. In both groups, the reconstructed breast had a larger volume. A-P projections were similar between the contralateral and the reconstructed breasts in the TE-implant group: 72.5 ± 3.21 mm versus 71.7 ± 3.5 mm (p > 0.05). The autologous reconstructed breast had statistically insignificant but less A-P projection compared to the contralateral breast (81.9 ± 16.1 mm versus 61.5 ± 9.5 mm; p > 0.05). Variance of A-P projection from the mean was additionally insignificant between the contralateral and reconstructed breasts. Both groups produced similar asymmetry scores based on global 3D comparison (TE-implant: 2.24 ± 0.3 mm; autologous: 1.96 ± 0.2 mm; p > 0.05). Lastly, when the autologous group was further subdivided into TRAM and DIEP cohorts, no significant differences in breast volume, A-P projection or symmetry existed. Using 3D imaging, we demonstrate that both TE-implant and autologous reconstruction can achieve symmetrical surgical results with the same number of operations. This study demonstrates that breast symmetry, while an important consideration in the breast reconstruction algorithm, should not be the sole consideration in a patient' decision to proceed with autologous versus TE-implant reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient satisfaction in unilateral and bilateral breast reconstruction.

BACKGROUND The goal of reconstruction after mastectomy is to provide a long-term and symmetric reconstruction. Providing symmetry entails different decision making when faced with a unilateral or bilateral reconstruction. In unilateral reconstruction, the goal is to match the contralateral breast; however, in bilateral reconstruction, symmetry between the reconstructed breasts is more important...

متن کامل

Shaping of the Unaffected Breast with Brava-Assisted Autologous Fat Grafting to Obtain Symmetry after Breast Reconstruction.

BACKGROUND In breast reconstruction, symmetry is a vital issue. However, when the original breast is unusually shaped or the patient desires augmentation at the time of reconstruction, obtaining symmetrical breasts becomes difficult. OBJECTIVES The authors performed shaping of unaffected breasts by Brava-assisted autologous fat grafting to enhance breast symmetry, and evaluated the clinical r...

متن کامل

Three-dimensional imaging provides valuable clinical data to aid in unilateral tissue expander-implant breast reconstruction.

The current approach to breast reconstruction remains largely subjective and is based on physical examination and visual-estimates of breast size. Thus, the overall success of breast reconstruction is limited by the inability of plastic surgeons to objectively assess breast volume and shape, which may result in suboptimal outcomes. A potential solution to this obstacle may be three-dimensional ...

متن کامل

Recurrent 8-Year Ongoing Unilateral Breast Seroma Formation after PIP Implant Removal—A Case Report and Review of the Literature

Late seroma formation is a rare complication after implant-based breast enlargement surgery and even less frequent after implant removal. This case report presents a case of painful recurrent seroma formation after the removal of a ruptured Poly Implants Prothèse implant. A 52-year-old patient presented herself in our clinic with a clinical history of recurrent unilateral seroma of the right br...

متن کامل

Contralateral Augmentation with a Transmidline Scarless Technique During Unilateral Breast Reconstruction Using Implants

BACKGROUND Unilateral breast reconstruction can be a challenge when attempting to achieve an aesthetically pleasing and symmetrical breast mound on the contralateral side. This study investigates the outcomes of using a contralateral augmentation transmidline scarless (CATS) technique to simultaneously augment the contralateral breast using implants. METHODS Between January 2004 and July 2016...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The breast journal

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2016