Comparing consistency of clear corneal incisions using a traditional diamond keratome and a newly designed diamond keratome

نویسندگان

  • Russell J Swan
  • Julia M Byrd
  • Daniel I Bettis
  • Randall J Olson
چکیده

PURPOSE To compare the consistency of incision architecture utilizing a traditional diamond keratome and a newly designed diamond keratome. METHODS We used a traditional diamond keratome and newly designed diamond keratome to create clear corneal incisions in human cadaveric donor eyes. Three surgeons with varying levels of experience made 30 incisions with each keratome; and the wound architecture was measured including incision lengths, epithelial and endothelial widths, and the central epithelial incision's deviation from a straight line entrance. RESULTS The mean absolute difference in right and left incision lengths (traditional: 0.182 ± 0.158 mm and new 0.088±0.077 mm [P<0.003]), mean absolute difference in epithelial and endothelial incision width (traditional: 0.181±0.144 mm and new 0.080±0.092 mm [P<0.002]), endothelial incision central deviation from a straight line (traditional: 0.128±0.242 mm and new -0.046±0.124 mm [P<0.001]) were all significantly more consistent with the newly designed diamond keratome than with the traditional diamond keratome. CONCLUSION The newly designed diamond keratome creates a more consistent clear corneal incision than a traditional diamond keratome across a variety of surgical skill levels and does not require advanced levels of training to achieve this consistency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of morphologic features of clear corneal incisions created with a femtosecond laser or a keratome.

PURPOSE To compare the morphology of clear corneal incisions (CCIs) created with a femtosecond laser (Catalys) or a keratome (2.65 mm steel) during phacoemulsification using anterior segment optical coherence tomography (AS-OCT) and analyze the intended versus the achieved morphologic characteristics of femtosecond laser-generated CCIs. SETTING Northwestern University Feinberg School of Medic...

متن کامل

P 231 Comparison of descements membrane damage following phacoemulsification using corneal valve incisions with 2 MM corneal or sclerocorneal tunnels

COMPARISON OF DESCBMET’S MEMBRANE DAMAGE FOLLOWING PHACOEMULSIFICATION USING CORNEAL VALVE INCISIONS WITH 2 MM CORNEAL OR SCLEROCORNEAL TUNNELS. TOULEMONT PJ’ , SERDAREVIC ON2, GROSS1 D3. ‘Dep. of Ophthalmol., Rennes I University (Fr.). 2Manhattan Eye, Ear and Throat Hospital, New York (USA) 3 Dep. of Ophthalmol., Rosario (Argentina) Puroose; We CO”lgJWC. Descemet’s membrane damage following ph...

متن کامل

P 234 The effect of dexamethasone 0.1% eye drops on the plasma cortisol levels and ACTH-concentrations following cataract surgery

COMPARISON OF DESCBMET’S MEMBRANE DAMAGE FOLLOWING PHACOEMULSIFICATION USING CORNEAL VALVE INCISIONS WITH 2 MM CORNEAL OR SCLEROCORNEAL TUNNELS. TOULEMONT PJ’ , SERDAREVIC ON2, GROSS1 D3. ‘Dep. of Ophthalmol., Rennes I University (Fr.). 2Manhattan Eye, Ear and Throat Hospital, New York (USA) 3 Dep. of Ophthalmol., Rosario (Argentina) Puroose; We CO”lgJWC. Descemet’s membrane damage following ph...

متن کامل

Cut edges and surface characteristics produced by different microkeratomes.

PURPOSE To determine the cutting characteristics of seven different microkeratomes and to compare the cut edges and surface characteristics of the corneas with respect to different keratome parameters, ie, blade oscillation frequencies and keratome speed. METHODS Lamellar keratectomies were performed using each microkeratome on eight freshly enucleated porcine corneas. The freshly cut corneal...

متن کامل

Razor blade section in cataract surgery.

There are many techniques of cataract extraction and many types of cataract knives have been devised to facilitate an ideal section. Ultrasharp diamond knives were introduced by Durham and Luntz (I968). Sharpness is essential whether the von Graefe knife, the keratome, or corneal scissors are used, and for this reason disposable cataract knives, keratomes, and Bard Parker blades are widely used...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015