Characterization of Flexible RF Microcoil Dedicated to Surface Mri
نویسندگان
چکیده
In Magnetic Resonance Imaging (MRI), to achieve sufficient Signal to Noise Ratio (SNR), the electrical performance of the RF coil is critical. We developed a device (microcoil) based on the original concept of monolithic resonator. This paper presents the used fabrication process based on micromoulding. The dielectric substrates are flexible thin films of polymer, which allow the microcoil to be form fitted to none-plane surface. Electrical characterizations of the RF coils are first performed and results are compared to the attempted values. Proton MRI of a saline phantom using a flexible RF coil of 15 mm in diameter is performed. When the coil is conformed to the phantom surface, a SNR gain up to 2 is achieved as compared to identical but planar RF coil. Finally, the flexible coil is used in vivo to perform MRI with high spatial resolution on a mouse using a small animal dedicated scanner operating at in a 2.35 T.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملIntraductal micro magnetic resonance imaging and spectroscopy
The majority of breast cancers originate in the mammary ducts. As such many diagnostic techniques introduce mmdiameter devices into the ducts through the nipple. Established intraductal techniques include ductal lavage, and white-light or fluorescence endoscopy. While reported values vary, these techniques typically suffer from low sensitivity and specificity. Similarly, Magnetic Resonance Imag...
متن کاملActively Detunable 8-channel Small Animal Transceive Volume Array for 9.4T MRI systems
Introduction Ultra-high field MRI systems for small animals have seen a rapid development over recent years in a continuous effort to enhance SNR and spectral resolution of MRI images. To circumvent the associated high-field B1 inhomogeneity problem, methods such as RF shimming and Transmit SENSE have been proposed [1-2]. To benefit from the advantages of these techniques, dedicated phased-arra...
متن کاملFabrication of microcoil/microsprings for novel chemical and biological sensing
This paper reports the fabrication of a novel microsensor structure using inductively coupled plasma source (ICP) dry etching process. The novel sensor is based on a SiO2/Si/SU-8 trilayered microcoil/microspring structure. The diameter of the microcoil was approximately 600 m. The ICP process and SU-8 exposing time are discussed. The SiO2 layer can be conveniently modified according to typical ...
متن کامل3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/0711.3326 شماره
صفحات -
تاریخ انتشار 2006