Correcting photon counts due to detector pile up

ثبت نشده
چکیده

Where B is the ratio variance to average, p is the after pulsing probability, I is the intensity in photon counts/s and t is the dead time. Ignoring for the moment the after pulsing effect, in the absence of other effects, the value of B will decrease linearly with the intensity with a slope given by 2t. The following graph is an example for the expected changes in B as a function of intensity for the avalanche photo detector (APD) with a dead time of 50 ns. We assume a sampling time of 8 us. This is typical of our mode of data acquisition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

متن کامل

A digital method for separation and reconstruction of pile-up events in germanium detectors.

The problem of pulse pile-up is very often encountered in precise measurements of γ-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather...

متن کامل

Use of streak camera for time - resolved

The use of a conventional streak camera for subnanosecond timeresolved fluorimetry is extended to the single-photon counting regime by utilizing intensified readout of the phosphor. The system achieves the usual k e y advantages of photon counting, namely single-photon sensitivity, large dynamic range and shot noise limited statistics, but also permits measurements of lower repetition rate and ...

متن کامل

Iterative correction for ‘pile-up’ in single-photon lifetime measurement

A novel iterative algorithm is proposed to correct for pulse, or photon, ‘pile-up’ in the measurement of temporal intensity profiles using time-correlated single-photon counting (TCSPC). Despite the existence of correction algorithms since 1968, most TCSPC experiments are operated in a very low photon-count mode to avoid pulse pile-up effects in the data. This is inefficient and time-consuming,...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015