A new approach for detection of leg movement using segmental electrical impedance changes.
نویسندگان
چکیده
The purpose of this paper is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depend on electrode placement, we determined the optimal electrode configurations for these movements by searching for high correlation coefficients, large impedance changes, and minimum interference in ten subjects (age: 20 +/- 4). Our optimal electrode configurations showed very strong relationships between the ankle joint angle and ankle impedance (gamma = - 0.913 +/- 0.03), between the knee joint angle and knee impedance (gamma = 0.944 +/- 0.02), and between the hip joint angle and hip impedance (gamma = 0.823 +/- 0.08). This study showed that lower leg movement could be easily measured by the impedance measurement system with two pairs of skin electrodes.
منابع مشابه
A New Nonlinear Autoregressive Exogenous (NARX)-Based Intra-Spinal Stimulation Approach to Decode Brain Electrical Activity for Restoration of Leg Movement in Spinally-Injured Rabbits
This study aims at investigation of stimulation by using intra-spinal signals decoded from electrocorticography (ECoG) assessments to restore the movements of the leg in an animal model of spinal cord injury (SCI). The present work comprised of three steps. First, ECoG signals and the associated leg joint changes (hip, knee, and ankle) in sedated healthy rabbits were recorded in different trial...
متن کاملThe Application of Bioelectrical Impedance to Monitor Leg Movement
The purpose of this study is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance cha...
متن کاملModified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...
متن کاملDetection of high impedance faults in distribution networks using Discrete Fourier Transform
In this paper, a new method for extracting dynamic properties for High Impedance Fault (HIF) detection using discrete Fourier transform (DFT) is proposed. Unlike conventional methods that use features extracted from data windows after fault to detect high impedance fault, in the proposed method, using the disturbance detection algorithm in the network, the normalized changes of the selected fea...
متن کاملOptimum electrode configuration for detection of leg movement using bio-impedance.
Impedances and joint angles were simultaneously measured during ankle and knee movements. The correlation coefficients of the joint angle and the impedance change from human leg movement were obtained using an electro-goniometer and a four-channel impedance measurement system. Because the impedance changes resulting from ankle and knee movements depended heavily on the electrode placement, we d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical engineering & technology
دوره 29 1 شماره
صفحات -
تاریخ انتشار 2005