Role of femoral anterior Bow in cephalomedullary nailing: finite element analysis and New index estimation

نویسندگان

  • Dong Ren
  • Yueju Liu
  • Ming Li
  • Zhaohui Song
  • Shuangquan Yao
  • Pengcheng Wang
چکیده

BACKGROUND Cephalomedullary Nail (CMN) is seen as the mainstay of internal fixation in femoral fractures. The purpose of the study was to present an accurate calculation method by simulating diverse anterior bow femoral models with finite element software. We hypothesized that anterior cortical penetration in distal femur would occur in patients whose femoral anterior bow was identified as too large for nailing by preoperative measurement of contralateral X-ray. METHODS A 31-year healthy male was selected for building 3D bone model through computed tomography (CT) scan of right femoral femur. In Creo Parametric 2.0, the middle section of the femur was twisted gradually to simulate the different femoral anterior bow. Ratio of chord height and half chord length, belonging to the middle section arc, was defined as the tangent value of the femoral anterior bow. The value corresponding to the penetration of the CMN at the distal femur was regarded as critical value, showing the extreme curvature for CMN. RESULT Three types of right femoral CMNs (ø10, 11, 12 mm × 350 mm; Smith-Nephew Co.) were involved in our study. The CMN passed through distal femur anterior cortex when the tangent value of the femoral anterior bow are 0.140185, 0.133073, 0.092415 respectively, and the corresponding central angle are 21.72°, 20.92°, 16.32°. CONCLUSIONS The tangent value of the femoral anterior bow would be a precise calculated method, that eliminate the deviation by description of ratio rather than length of radius. An application of this preoperative evaluation can aid surgeons during surgical planning. TRIAL REGISTRATION Retrospectively registered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of cephalomedullary nail fit in the femur using 3D computer modelling: a comparison between 1.0 and 1.5m bow designs

BACKGROUND The radius of curvature (ROC) misfit of cephalomedullary nails during anterograde nailing can lead to complications such as distal anterior cortical encroachment. This study quantified the anatomical fit of a new nail with 1.0-m ROC (TFN-ADVANCED(™) Proximal Femoral Nailing System [TFNA]) compared with a nail with 1.5-m ROC (Gamma3 Long Nail R1.5 [Gamma3]). METHODS We generated 63 ...

متن کامل

A New Restructured Shaded Pole Induction Motor- 3D Finite Element Analysis and Experimental Verification

Shaded pole induction motors, despite the simplicity and low cost, are difficult to analyze particularly in the equivalent circuit methods, due to the asymmetric structure, saturation, harmonics, inaccurate estimation of leakage inductances and skew. Hence, 3D numerical methods could be very useful in the design and optimization stage. This paper presents the 3D transient finite element analysi...

متن کامل

CORR Insights ®: Intramedullary nailing of femoral diaphyseal metastases: is it necessary to protect the femoral neck?

BACKGROUND Intramedullary nailing is the accepted form of treatment for impending or pathologic fractures of the femoral diaphysis. Traditional teaching promotes the use of a cephalomedullary nail so that stabilization is provided for the femoral neck in the event that a future femoral neck metastasis develops. However, that approach may add cost, surgical time, blood loss, and added radiation ...

متن کامل

Intramedullary nailing without curettage and cement augmentation for the treatment of impending and complete pathological fractures of the proximal or midshaft femur.

Metastases in the proximal femur and in the femoral diaphysis are usually treated with either cephalomedullary or intramedullary nailing. The benefit of curettage and augmentation of the nail with methyl methacrylate remains controversial. The authors retrospectively studied the outcomes with cephalomedullary and intramedullary nailing without curettage and methyl-methacrylate augmentation for ...

متن کامل

Comparative study between lateral decubitus and traction table for treatment of pertrochanteric fractures with cephalomedullary nails☆

OBJECTIVE To perform a retrospective radiographic assessment of the reduction and implant position in the femoral head in patients with pertrochanteric fractures treated with cephalomedullary nailing in the lateral position versus traction table. METHODS Radiographs of patients with pertrochanteric fracture of the femur treated with cephalomedullary nailing in the lateral position and tractio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016