Fluorescence microlymphography: diagnostic potential in lymphedema and basis for the measurement of lymphatic pressure and flow velocity.

نویسندگان

  • A Bollinger
  • B R Amann-Vesti
چکیده

Fluorescence microlymphography (FML) is an almost atraumatic technique used to visualize the superficial skin network of initial lymphatics through the intact skin of man. Visualization was performed with an incident light fluorescence microscope following subepidermal injection of minute amounts of FITC-dextran 150,000 using microneedles. Emanating from the bright dye depot, the surrounding network of microvessels is filled, documentation performed by photography or video film. In congenital Milroy lymphedema, a lack of microlymphatics (aplasia) is typical while in other primary lymphedemas and in secondary lymphedema after mastectomy or irradiation of proximal lymph nodes, the network remains intact but the depicted area is enlarged. Lymphatic microangiopathy characterized by obliterations of capillary meshes or mesh segments develops in phleboedema with trophic skin changes, progressive systemic sclerosis and Fabry's disease. In lipedema, lymphatic microaneurysms are stained. Microlymphatic pressure may also be measured using FML. For this purpose, glass micropipettes are inserted into the capillaries by means of a micromanipulator and pressure is determined by the servo-nulling technique. Normal subjects produced significantly lower pressure (7.9 +/- 3.4 mmHg) compared to patients with primary lymphedema (15.0 +/- 5.1 mmHg, p<0.001). This characteristic lymphatic hypertension may be improved by complex physiotherapy or local application of prostaglandins. Additionally, a modification of the FML procedure can be used to measure lymphatic capillary flow velocity in controls and patients. FML is suited to confirm the clinical diagnosis of lymphedema, contributes to distinguish among various forms of edema, and is useful in clinical research. In addition, FML has also become a tool for experimental animal studies including the depiction of gastric microlymphatics, the measurement of flow velocity in the naked mouse tail, and in evaluation of lymphangiogenesis in a model of Milroy disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescence microlymphography.

Microneedles, 0.2 mm o.d., were connected to a microsyringe and mounted on a micromanipulator. Under microscopic control, 0.01 ml of a 25% solution of FITC-labeled dextran-40 or dextran-150 were injected into the subepidermis at the big toe near the nailfold or in the medial ankle region. Fluorescence intravital microscopy revealed a network of lymphatic microvessels. The comparison with recent...

متن کامل

Morphologic and functional changes of the microlymphatic network in patients with advancing stages of primary lymphedema.

Using fluorescent microlymphography, we examined the morphology andfunctional characteristics of the microlymph-vascular network in 36 subjects including 9 patients with "compressible" lymphedema (Group I), 14 with minimally compressible lymphedema (Group II), 9 with noncompressible lymphedema (Group III), and 4 healthy individuals. As lymphedema progressedfrom early to advanced stages (Group I...

متن کامل

Primary Congenital Lymphedema in the Upper Limbs of Children: Case Series

The aim of the present study was to report a case series involving the treatment of primary congenital lymphedema using the Godoy method. Eight children (seven girls and one boy) with primary congenital lymphedema of the upper limbs treated at the Godoy Clinic. A retrospective clinical trial was conducted to evaluate treatment for primary congenital l...

متن کامل

Two-fluid Electrokinetic Flow in a Circular Microchannel (RESEARCH NOTE)

The two-fluid flow is produced by the combined effects of electroosmotic force in a conducting liquid and pressure gradient force in a non-conducting liquid. The Poisson-Boltzmann and Navier-Stokes equations are solved analytically; and the effects of governing parameters are examined. Poiseuille number increases with increasing the parameters involved. In the absence of pressure gradient, the ...

متن کامل

Mean Velocity and Static Pressure in a Sharp-edge Circular Nozzle Jet

An axisymmetric jet issued from a sharp edged circular convergent nozzle has been studied experimentally in the near field at Reynolds number 5.3x104  to search the saddle shape behavior of mean velocity and the role of mean static pressure in the jet flow. Due to the vena contracta effect the centerline mean velocity of the jet increases about 4.2% of its exit value and corresponding decrease ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lymphology

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2007