Augmentation of Pedicle Screw Fixation with a Bioactive Cement

نویسندگان

  • Turner
  • Gillies
  • Svehla
  • Saito
  • Walsh
چکیده

Introduction Pedicle screws are commonly used in posterior internal fixation systems to stabilise the spine for fusion procedures. Rigid fixation systems place high requirements on the load-carrying capacity at the screw-bone interface. Poor bone quality decreases the integrity of this interface, increasing screw micromotion and consequently reducing screw stability and possibly fusion success. In severely osteopenic bone, pedicle screw use may be ruled out completely.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Strategies to Improve Fixation in the Osteoporotic Spine: The Effects of Tapping, Cement Augmentation, and Screw Trajectory

Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw ...

متن کامل

Possible usage of cannulated pedicle screws without cement augmentation

BACKGROUND: The use of pedicle screws is becoming increasingly popular for spinal surgery practice as the technology advances. Screw pullout due to bone quality and loading conditions is one of the most common problems observed after pedicle screw fixation. Several solutions were studied to prevent screw pullout. These can be investigated under three main categories: screw design, expandable sc...

متن کامل

Pulmonary cement embolism during cement augmentation of pedicle screw fixation: a case report.

We present a case of pulmonary cement embolism during cement augmentation of pedicle screw fixation for severe degenerative scoliosis. During intra-operative C-arm fluoroscopy, a radio-opaque substance was incidentally noted to pulsate in synchrony with the patient's heartbeat. A diagnosis of pulmonary cement embolism was made. The patient was treated with coumarin for 6 months. He made a good ...

متن کامل

A Biomechanical Comparison of Expansive Pedicle Screws for Severe Osteoporosis: The Effects of Screw Design and Cement Augmentation

Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the bone/screw interface when expansive screws are used with or without cement augmentation. Herein, four designs for expansive pedicle screws with ...

متن کامل

Pullout performance comparison of pedicle screws based on cement application and design parameters.

Pedicle screws are the main fixation devices for certain surgeries. Pedicle screw loosening is a common problem especially for osteoporotic incidents. Cannulated screws with cement augmentation are widely used for that kind of cases. Dual lead dual cored pedicle screw has already given promising pullout values without augmentation. This study concentrates on the usage of dual lead dual core wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001