Lipid infusion through malpositioned central venous catheter: head ultrasound features.
نویسندگان
چکیده
Properly placed central venous catheters have been effective in establishing prolonged access for total parenteral nutrition infusion in ill neonates. However, malposition of the catheter may lead to lethal complications. Malposition and infusion into the epidural venous plexus is most commonly diagnosed on the basis of radiographs and has been confirmed by lumbar puncture. Several studies describe catheter malposition and associated complications. None, however, demonstrate head ultrasound features. We present sonographic findings in a patient who received hyperalimentation for 15 days through a malpositioned lower extremity peripherally inserted central venous catheter.
منابع مشابه
Significance of a curled central venous catheter tip.
A malpositioned central venous catheter can cause constant excessive pressure on one particular area of a central vein, thus leading to perforation and hydrothorax. The following is a case report of an iatrogenic hydrothorax caused by a malpositioned central venous catheter. The subtle sign of malposition is a slightly curled catheter tip.
متن کاملA catheter malpositioned patient with pain and paresthesia
We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...
متن کاملLocation of the Central Venous Catheter Tip With Bedside Ultrasound in Young Children: Can We Eliminate the Need for Chest Radiography?
OBJECTIVE To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. DESIGN Prospective observational study. SETTING PICU of a university hospital. PATIENTS Patients aged 0-14 who required a central venous catheter. INTERVENTION None. MEASUREMENTS AND MAIN RESULTS Central venous catheter tip location was confirmed by ultrasound an...
متن کاملFatal Septic Internal Jugular Vein-Sigmoid Sinus Thrombosis Associated with a Malpositioned Central Venous Catheter
Septic internal jugular vein-sigmoid sinus thrombosis (IJV-SST) associated with a malpositioned central venous catheter is a rare condition. It is potentially life-threatening and necessitates early diagnosis and rapid administration of appropriate medications. Unfortunately, it is difficult to diagnose due to vague clinical presentations. Several studies such as CT, MRI, and cerebral angiograp...
متن کاملComparing the anatomy of the intrathoracic systemic central venous system in Iranian pediatrics and adults based on chest CT scan and evaluation of rate of catheter malposition in children
Background: Central venous catheterization is a procedure that is being performed frequently especially in critical clinical settings. In such conditions, good knowledge of the surface anatomy of venous structures is vital to avoid possible complications which could result in life-threatening situations such as bleeding and pneumothorax. Considering the difference between venous anatomy of chil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of radiology case reports
دوره 3 11 شماره
صفحات -
تاریخ انتشار 2009