Automated, real-time fresh gas flow recommendations alter isoflurane consumption during the maintenance phase of anesthesia in a simulator-based study.

نویسندگان

  • Isaac Luria
  • Samsun Lampotang
  • Wilhelm Schwab
  • Lou Ann Cooper
  • David Lizdas
  • Nikolaus Gravenstein
چکیده

BACKGROUND The Low Flow Wizard (LFW) provides real-time guidance for user optimization of fresh gas flow (FGF) settings during general inhaled anesthesia. The LFW can continuously inform users whether it determines their FGF to be too little, efficient, or too much, and its color-coded recommendations respond in real time to changes in FGF performed by users. Our study objective was to determine whether the LFW feature, as implemented in the Dräger Apollo workstation, alters FGF selection and thereby volatile anesthetic consumption without affecting patient care. METHODS To reduce potentially confounding variables, we used a human patient simulator that consumes and exhales volatile anesthetics. Standard monitoring was provided for the patient initially with invasive arterial blood pressure added after anesthetic induction. In this within-group study, each of 17 participants acted as his or her own control. Each participant was asked to anesthetize an identical simulated patient twice using a Dräger Apollo workstation, first with the LFW feature disabled and subsequently enabled. The volatile anesthetic was isoflurane. Both simulation runs were set up to have similar time durations for the different phases of anesthesia: induction, incision, and maintenance. Emergence was not simulated. The isoflurane vaporizer was weighed before and after each simulation run on a digital scale to verify total computed volatile liquid anesthetic consumption. In addition, the product of FGF (reported by the Apollo) times the isoflurane volumetric concentration (sampled by a multigas analyzer at the equivalent of the FGF hose for the Apollo) was integrated over time to obtain isoflurane consumption rate (on-the-fly anesthetic consumption rate measurement). RESULTS The maintenance isoflurane consumption rate and FGF were significantly lower with the LFW display enabled than without (P = 0.005). The mean reduction in FGF was 53.6% (95% confidence interval, 39.2%-67.9%). There was no significant difference in alveolar isoflurane concentration (P = 0.13 for differences <0.1%). The isoflurane consumption measurement closely matched the consumption measured via the digital scale. CONCLUSIONS Our data in a simulated anesthetic suggest that enabling the display of FGF efficiency data by the LFW results in a median percent reduction in volatile liquid anesthetic consumption rate of 53.2%. Since the lower limit of the 95% confidence interval for the median is 39.4%, this finding is likely to translate into cost savings and less waste anesthetic gas generated in the clinical setting and released into the atmosphere.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مزایای مانیتورینگ Bispecteral index در افراد چاق کاندید کوله‌سیستکتومی لاپاراسکوپیک در بیهوشی با ایزوفلوران

Background: Morbid obesity is associated with a some of significant comorbidities. Early and uneventful postoperative recovery of obese patients remains a challenge for anesthesiologists. It seems Bispecteral Index (BIS) monitoring may reduce drug usage and hasten recovery time in inhalation anesthesia. The aim of this study was to investigate the effect of BIS monitoring on intraoperative isof...

متن کامل

Effects of tail fat on recovery times of anesthesia with isoflurane in fat-tailed Iranian Lori-Bakhtiyari lambs

In the present study, the effect of tail fat on recovery times in intact sheep and sheep with a ligated median sacral artery following similar anesthetic exposure with isoflurane was investigated. This study was performed using seven healthy fat-tailed Iranian Lori-Bakhtiyari ewe lambs. The lambs were anesthetized twice at two week intervals (the experiment was performed in two stages). After m...

متن کامل

Reducing wastage of inhalation anesthetics using real-time decision support to notify of excessive fresh gas flow.

BACKGROUND Reduced consumption of inhalation anesthetics can be safely achieved by reducing excess fresh gas flow (FGF). In this study the authors describe the use of a real-time decision support tool to reduce excess FGF to lower, less wasteful levels. METHOD The authors applied a decision support tool called the Smart Anesthesia Manager™ (University of Washington, Seattle, WA) that analyzes...

متن کامل

Preparation of the Dräger Primus anesthetic machine for malignant hyperthermia-susceptible patients.

PURPOSE Preparation of anesthesia machines for patients who are susceptible to malignant hyperthermia includes flushing the machine with vapour-free fresh gas to washout residual anesthetic agents. To establish guidelines for the preparation of the Dräger Primus machine, we compared the washout profiles for isoflurane and sevoflurane in the Dräger Primus and Ohmeda Excel 210 anesthesia machines...

متن کامل

The effect of a model-based predictive display on the control of end-tidal sevoflurane concentrations during low-flow anesthesia.

We have shown that a multicompartment model accurately predicts end-tidal (ET) sevoflurane (sevo) and isoflurane concentrations. The model has been adapted to use real-time fresh gas flow and vaporizer settings to display a 10-min prediction of ET sevo concentrations. In this study, we evaluated the effect of the predictive display on the speed and accuracy of changes in ET sevo by the anesthes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 117 5  شماره 

صفحات  -

تاریخ انتشار 2013