Factors affecting visualization rates of internal mammary sentinel nodes during lymphoscintigraphy.

نویسندگان

  • Borys R Krynyckyi
  • Hyolim Chun
  • Hyun Ho Kim
  • Yasser Eskandar
  • Chun K Kim
  • Josef Machac
چکیده

UNLABELLED There is great variation in the reported frequency of internal mammary (IM) sentinel node (SN) visualization. We observed a marked increase in our IM SN detection rate after 2 factors were changed simultaneously: depth of perilesional injection and dose. METHODS A retrospective review of 82 consecutive patients (group 1) was compared with 61 consecutive patients (group 2) after changing the depth of perilesional injections and dose. Both groups had perilesional injections of (99m)Tc-sulfur colloid followed by intradermal injections at the areolar cutaneous junction. For group 2, activity was increased in all patients scheduled for next-day surgery. Group 2 had perilesional injections on top of, beside, and just below the estimated level of the tumor in an infiltrative manner, versus injections just on top of and beside the tumor as performed for group 1. RESULTS The rates of IM SN visualization were 4.9% (4/82) for group 1 and 23.0% (14/61) for group 2 (P < 0.003). IM SNs were hotter in group 2 than in group 1. The total number of IM SNs detected per patient was also higher for group 2 than for group 1: 2.1 and 1.2, respectively. In group 2, patients with small breasts had an IM SN visualization rate of 46.2%; those with medium breasts, 21.1%; and those with large breasts, 0% (P < 0.017). In group 2, primary lesions located medially had a higher rate of IM SN visualization than did lesions located laterally: 38.9% (7/18) and 16.2% (6/37), respectively (P = 0.066). Dose was not a statistically significant factor within group 2 or group 1 when comparing IM SN visualization rate for doses above or below the mean or median. CONCLUSION Modification of just these 2 factors resulted in a striking change in our IM SN detection rates. The injection depth was the most important factor. Breast size had a marked effect on the probability of detecting IM SNs. This suggests that the variation in detection rates reported in the literature could be at least partly dependent on variations in these factors, among others. Many surgeons do not routinely harvest IM SNs, but information about their presence can potentially alter treatment decisions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonvisualization of sentinel node by lymphoscintigraphy in advanced breast cancer

Previous studies have shown that an increased number of axillary lymph nodes with metastatic involvement is associated with nonvisualization of lymph nodes during lymphoscintigraphy. We report a case of nonvisualization of the sentinel node during lymphoscintigraphy in a female with advanced breast cancer to support this association. Although many factors can affect visualization of the sentine...

متن کامل

Time frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information

Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...

متن کامل

Sentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients

Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...

متن کامل

The value of lateral lymphoscintigraphy images of the pelvis for gynecological cancers: Are they necessary?

Introduction: In the current study we evaluated the incremental value of lateral pelvic lymphoscintigraphy imaging of endometrial or cervical cancer patients who underwent sentinel node mapping. Methods: Operable endometrial and cervical cancer patients without clinical or paraclinical evidence of lymph node involvement were included in the study. The day before surgery the patients were sent ...

متن کامل

Fallacies of preoperative lymphoscintigraphy in detecting sentinel node in breast cancer

BACKGROUND: Preoperative lymphoscintigraphy is one of the three methods of evaluating sentinel nodes in patients with breast cancer; however, it has been reported to have a high false negative rate. CASE PRESENTATIONS: We report here two cases where the preoperative lymphoscintigraphy was found to be fallacious. A 44-year-old female with T2N0 breast cancer underwent preoperative lymphoscintigra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 44 9  شماره 

صفحات  -

تاریخ انتشار 2003