Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source.
نویسندگان
چکیده
Investigation of the spatial distribution of lipids in cell membranes can lead to an improved understanding of the role of lipids in biological function and disease. Time-of-flight secondary ion mass spectrometry is capable of molecule-specific imaging of biological molecules across single cells and has demonstrated potential for examining the functional segregation of lipids in cell membranes. In this paper, standard SIMS spectra are analyzed for phosphatidylethanolamine, phosphatidylglycerol, phosphatidylserine, phosphatidylinositol, cholesterol, and sulfatide. Importantly, each of the lipids result in signature mass spectral peaks that allow them to be identified. These signature peaks are also useful for imaging experiments and are utilized here to simultaneously image lipids on a micrometer scale in picoliter vials. Because the low secondary ion signal achieved for lipids from an atomic primary ion source makes cell-imaging experiments challenging, improving signal with cluster primary ion sources is of interest. Here, we compare the secondary ion yield for seven lipids using atomic (Ga+ or In+) ion sources and a buckminsterfullerene (C60+) primary ion source. A 40-1000-fold improvement in signal is found with C60+ relative to the other two ion sources, indicating great promise for future cellular imaging applications using the C60+ probe.
منابع مشابه
MS/MS analysis and imaging of lipids across Drosophila brain using secondary ion mass spectrometry
Lipids are abundant biomolecules performing central roles to maintain proper functioning of cells and biological bodies. Due to their highly complex composition, it is critical to obtain information of lipid structures in order to identify particular lipids which are relevant for a biological process or metabolic pathway under study. Among currently available molecular identification techniques...
متن کاملIntact lipid imaging of mouse brain samples: MALDI, nanoparticle-laser desorption ionization, and 40 keV argon cluster secondary ion mass spectrometry
We have investigated the capability of nanoparticle-assisted laser desorption ionization mass spectrometry (NP-LDI MS), matrix-assisted laser desorption ionization (MALDI) MS, and gas cluster ion beam secondary ion mass spectrometry (GCIB SIMS) to provide maximum information available in lipid analysis and imaging of mouse brain tissue. The use of Au nanoparticles deposited as a matrix for NP-L...
متن کاملSingle-cell lipidomics: characterizing and imaging lipids on the surface of individual Aplysia californica neurons with cluster secondary ion mass spectrometry.
Neurons isolated from Aplysia californica , an organism with a well-defined neural network, were imaged with secondary ion mass spectrometry, C(60)-SIMS. A major lipid component of the neuronal membrane was identified as 1-hexadecyl-2-octadecenoyl-sn-glycero-3-phosphocholine [PC(16:0e/18:1)] using tandem mass spectrometry (MS/MS). The assignment was made directly off the sample surface using a...
متن کاملMolecule-specific imaging with mass spectrometry and a buckminsterfullerene probe: application to characterizing solid-phase synthesized combinatorial libraries.
We employ a newly developed buckminsterfullerene (C(60)) primary ion beam with time-of-flight secondary ion mass spectrometry to create molecule-specific images of resin particles employed in the solid-phase synthesis of peptide combinatorial libraries. This new cluster ion source, when operated at an incident energy of 20 keV, is remarkably effective at desorbing small peptides directly from a...
متن کاملHigh-spatial and high-mass resolution imaging of surface metabolites of Arabidopsis thaliana by laser desorption-ionization mass spectrometry using colloidal silver.
High-spatial resolution and high-mass resolution techniques are developed and adopted for the mass spectrometric imaging of epicuticular lipids on the surface of Arabidopsis thaliana. Single cell level spatial resolution of approximately 12 mum was achieved by reducing the laser beam size by using an optical fiber with 25 mum core diameter in a vacuum matrix-assisted laser desorption ionization...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 77 19 شماره
صفحات -
تاریخ انتشار 2005