Non rigid respiratory motion correction in whole body PET/MR imaging

نویسندگان

  • Hadi Fayad
  • Holger Schmidt
  • Christian Wuerslin
  • Dimitris Visvikis
چکیده

INSERM UMR1101, LaTIM, Brest, France Respiratory motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies include the use of respiratory synchronized gated frames which lead to low signal to noise ratio (SNR) given that each frame contains only part of the count available throughout an average PET acquisition. In this work, 4D MRI extracted elastic transformations were applied to list-mode data either inside the image reconstruction or to the reconstructed respiratory synchronized images to obtain respiration corrected PET images. Five patient datasets acquired on the SIEMENS mMR PET/MR system were used. T1-weighted 4D MR images were registered to the end expiration MR image using an elastic B-spline registration algorithm to derive deformation matrices used to account for the respiratory motion. The derived matrices were subsequently applied during the List Mode OSEM PET image reconstruction of the original emission list-mode data. The corrected images were compared with those produced by applying the elastic transformation after reconstructing PET frames followed by summing the realigned gated frames, as well as with uncorrected motion averaged images. Significant improvement was obtained by using any of the two respiratory motion correction techniques compared to uncorrected motion average images (>30% differences in tumor position and size and 25% SNR increase). Both correction approaches lead to nearly equivalent improvements (differences of <8% and <6% for the lesion FWHM and the SNR respectively). A list-mode reconstruction based respiratory motion correction for PET has been implemented and its performance evaluated. This approach was based on the use of elastic transformations derived from 4D MRI during PET image reconstrucion. Our results show significant respiratory motion compensation when compared to the motion average PET images, with slightly better contrast and SNR compared to an equivalent 4D PET image space elastic motion correction method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Technical Challenges & Opportunities of PET/MR: An Overview

Following PET/CT, PET/MR is the newest diagnostic whole-body hybrid imaging modality. Simultaneous PET and MR data acquisition requires novel technical solutions and offers new diagnostic opportunities. Attenuation correction (AC) and motion correction (MC) of PET data are current hot topics in PET/MR hybrid imaging research. The added diagnostic value of PET/MR in whole-body imaging is current...

متن کامل

Highly efficient respiratory gating in whole heart MR employing non-rigid retrospective motion correction

Introduction: Three-dimensional whole heart imaging becomes the method of choice in various cardiac applications [1] as it avoids extensive planning of imaging slices and allows reconstructing arbitrary slice orientations. The drawback of the method is a relatively long scan time (on the order of several minutes) which requires motion compensation to suppress motion artifacts. A typical approac...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014