Tropospheric column ozone: matching individual profiles from Aura OMI and TES with a chemistry-transport model

نویسندگان

  • Q. Tang
  • M. J. Prather
چکیده

Of all satellite measurements of ozone, only two instruments have coincident, spatially overlapping measurements to allow direct comparison of tropospheric column ozone (TCO): the Ozone Monitoring Instrument (OMI) and the Tropospheric Emission Spectrometer (TES) on the NASA Aura spacecraft. For two years (2005–2006), we collect all observations between 60 S and 60 N from nadir (∼65 000 from OMI and TES) and cross-track swaths (∼30 000 000 from OMI) and compare with a chemistrytransport model (CTM) simulating each observation with corresponding spatial and temporal coincidence. Highfrequency TCO variations are indicative of stratospheric intrusions of ozone-rich air, and the individual, level 2 data provide access to these short-lived phenomena. Although we can identify some seasonal and large-scale biases in the model, the CTM as a transfer standard identifies weaknesses in the observations and further helps quantify the measurement noise of individual profiles. The relatively noise-free CTM bridges these two satellite measurements and improves their cross-validation to better precision than a simple direct comparison. Previous validation studies of TES TCO versus ozonesondes found a bias of about +4 Dobson Units (DU) for large regions. The three-way comparison and the CTM transfer method that use a far greater number of coincidences, indicate that monthly zonal mean OMI-TES TCO biases fall within 5–10 %, and thus quantifies the zonal mean OMI TCO bias at a few DU. For small regions (i.e., 5× 5), however, the monthly mean OMI-TES differences can exceed ± 10 DU at many places (e.g., tropics for the direct OMI-TES comparison) due to different tropospheric sensitivities of the two instruments at these locations. Partly removing the influence of different sensitivities by applying the CTM as the transfer standard, the OMI-TES differences generally decrease, especially over the tropics. In addition, the CTM-TES comparison split into day versus night observations shows no apparent bias in TES at very low levels, ±1 DU. These OMI-TES-CTM comparisons highlight the importance of the a priori ozone profiles that went into each satellite retrieval, including a false agreement due to CTM-a priori similarity, and the importance of including the vertical information (i.e., averaging kernel) in the retrieval products. This study also highlights the advantages of overlapping measurements in terms of cross-validation and the application of a model as the transfer standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone

[1] The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA’s Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and airc...

متن کامل

Improved tropospheric ozone profile retrievals using OMI and TES radiances

[1] We perform a study for characterizing the vertical resolution of tropospheric ozone profile retrievals from the combination of simulated ultraviolet (UV) and thermal infrared (TIR) observations that are representative of the EOS Aura Ozone Monitoring Instrument (OMI) and the Tropospheric Emission Spectrometer (TES). Under the low thermal contrast conditions used for this simulation, we find...

متن کامل

Evaluation of tropospheric ozone columns derived from assimilated GOME ozone profile observations

Tropospheric O3 column estimates are produced and evaluated from spaceborne O3 observations by the subtraction of assimilated O3 profile observations from total column observations, the so-called Tropospheric O3 ReAnalysis or TORA method. Here we apply the TORA method to six years (1996–2001) of ERS-2 GOME/TOMS total O3 and 5 ERS-2 GOME O3 profile observations using the TM5 global chemistry-tra...

متن کامل

Intercomparison methods for satellite measurements of atmospheric composition: application to tropospheric ozone from TES and OMI

We analyze the theoretical basis of three different methods to validate and intercompare satellite measurements of atmospheric composition, and apply them to tropospheric ozone retrievals from the Tropospheric Emission Spectrometer (TES) and the Ozone Monitoring Instrument (OMI). The first method (in situ method) uses in situ vertical profiles for absolute instrument validation; it is limited b...

متن کامل

The zonal structure of tropical O3 and CO as observed by the Tropospheric Emission Spectrometer in November 2004 – Part 2: Impact of surface emissions on O3 and its precursors

The impact of surface emissions on the zonal structure of tropical tropospheric ozone and carbon monoxide is investigated for November 2004 using satellite observations, in-situ measurements, and chemical transport models in conjunction with inverse-estimated surface emissions.Vertical ozone profiles from the Tropospheric Emission Spectrometer (TES) and ozone sonde measurements from the Souther...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012