A user-friendly Matlab program and GUI for the pseudorotation analysis of saturated five-membered ring systems based on scalar coupling constants

نویسندگان

  • Pieter MS Hendrickx
  • José C Martins
چکیده

BACKGROUND The advent of combinatorial chemistry has revived the interest in five-membered heterocyclic rings as scaffolds in pharmaceutical research. They are also the target of modifications in nucleic acid chemistry. Hence, the characterization of their conformational features is of considerable interest. This can be accomplished from the analysis of the 3J(HH) scalar coupling constants. RESULTS A freely available program including an easy-to-use graphical user interface (GUI) has been developed for the calculation of five-membered ring conformations from scalar coupling constant data. A variety of operational modes and parameterizations can be selected by the user, and the coupling constants and electronegativity parameters can be defined interactively. Furthermore, the possibility of generating high-quality graphical output of the conformational space accessible to the molecule under study facilitates the interpretation of the results. These features are illustrated via the conformational analysis of two 4'-thio-2'-deoxynucleoside analogs. Results are discussed and compared with those obtained using the original PSEUROT program. CONCLUSION A user-friendly Matlab interface has been developed and tested. This should considerably improve the accessibility of this kind of calculations to the chemical community.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Implementation of a Complementary Treatment Planning Software for the GZP6 HDR Brachytherapy System (GZP6 CTPS)

Introduction: Brachytherapy is one of the most common treatment modalities for gynecological cancer. The GZP6 brachytherapy system is one of the devices utilized in Iran. It has been considered particularly due to its low cost compared to other more complete and established systems. This system has some deficiencies including lack of a treatment planning software for non-predefined treatments, ...

متن کامل

A free user friendly program for evaluation of radiotherapy plans based on different dose response models

Introduction: Radiotherapy (RT) plan evaluation using dose response models has become a feasible approach in routine clinical practice. Although there are several tools for this task, they suffer from limitations including number of different dose response models and parameters. In the present study, we aimed to develop a free program for RT plan evaluation based on a variety ...

متن کامل

A Survey of Anticancer Effect of Some Five- and Six-Membered Palladium (II) Complexes (Containing Bidentate Phosphorus Ligands) on Caco-2 Colon Cancer Cell Line

Background and Objectives: Transition metal complexes possess a variety of biological and pharmacological activities, such as antitumor, antimicrobial, anti-inflammatory, anti-diabetic, and free radical scavenging. Many studies have been carried out on platinum-based chemotherapy agents, however, most attention has been paid to non-platinum metal-based agents in order to find different metal comp...

متن کامل

A Novel MATLAB GUI Comparative Technique to Evaluate Generated Frequency and Saturated Magnetizing Reactance of A 3-φ SEIG

Steady state analysis of a 3-φ SEIG is generally done through mathematical modeling of its equivalent circuit. The impedance model can be reduced in terms of two nonlinear simultaneous equations consisting of unspecified variables as magnetizing reactance Xm and generated frequency F. The steady state performance analysis of SEIG becomes uncomplicated once the values of Xm and F are explicitly ...

متن کامل

InRaDoS: An internal radiation dosimetry computer program

Introduction: Internal radiation dosimetry is important from a radiation protection point of view and can help to optimize the radiation dose delivered to the workers, public, and patients. It has a rather simple protocol but needs a large amount of data. Therefore, it is difficult to do on a routine basis. The use of computer programs makes internal radiation dosimetry simpler...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemistry Central Journal

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008