Accuracy of Visual Scoring and Semi-Quantification of Ultrasound Strain Elastography – A Phantom Study
نویسندگان
چکیده
PURPOSE The aim of this study was to evaluate the performance of strain elastography in an elasticity phantom and to assess which factors influenced visual scoring, strain histograms and strain ratios. Furthermore this study aimed to evaluate the effect of observer experience on visual scorings. MATERIALS AND METHODS Two operators examined 20 targets of various stiffness and size (16.7 to 2.5 mm) in an elasticity phantom at a depth of 3.5 cm with a 5-18 MHz transducer. Two pre-settings were used yielding 80 scans. Eight evaluators, four experienced, four inexperienced, performed visual scorings. Cut-offs for semi-quantitative methods were established for prediction of target stiffness. Data was pooled in two categories allowing calculations of sensitivity and specificity. Statistical tests chi-square test and linear regression as relevant. RESULTS Strain ratios and strain histograms were superior to visual scorings of both experienced and inexperienced observers (p = 0.025, strain histograms vs. experienced observers, p<0.001, strain histograms vs. inexperienced observers, p = 0.044 strain ratios vs. experienced observers and p = 0.002 strain ratios vs. inexperienced observers). No significant difference in predicting target stiffness between strain ratios and strain histograms (p = 0.83) nor between experienced and inexperienced observers (p = 0.054) was shown when using four categories. When pooling data in two groups (80 kPa/45 kPa vs. 14/8 kPa) the difference between the observers became significant (p<0.001). Target size had a significant influence on strain ratios measurements (p = 0.017) and on visual scorings (p<0.001) but not on the strain histograms(p = 0.358). Observer experience had significant effect on visual scorings(p = 0.003). CONCLUSION Strain ratios and strain histograms are superior to visual scoring in assessing target stiffness in a phantom. Target size had a significant impact on strain ratios and visual scoring, but not on strain histograms. Experience influenced visual scorings but the difference between experienced and inexperienced observers was only significant when looking at two classes of target stiffness.
منابع مشابه
Investigation of Shape Functions Role on the Mesh-free Method Application in Soft Tissue Elastography
In current study, The Mesh-free method based on weak-form formulation coupled with the ultrasound imaging technique is developed. This problem consists in computing the deformation of an elastic non-homogenous phantom by numerical methods (both Mesh-free and Finite Element) and converge their results to the measured deformation by the ultrasound. The shape functions of Mesh-free are approximate...
متن کاملSemi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis
Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT. We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS). ...
متن کاملMyocardial perfusion SPECT: Perfusion quantification
Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically. Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...
متن کاملUse of Ultrasound Elastography in Characterization of Solid Breast Lesions
Purpose: To study the role of strain ultrasound elastography in diagnosis of solid breast lesions, and evaluate its capability in differentiating benign from malignant lesions, in comparison to histopathological diagnosis taken as the reference standard. Patients and Methods: A total of eligible 28 female patients with solid breast masses, were subjected in our prospective study; sampled in a s...
متن کاملUltrasound frame rate requirements for cardiac elastography: experimental and in vivo results.
Cardiac elastography using radiofrequency echo signals can provide improved 2D strain information compared to B-mode image data, provided data are acquired at sufficient frame rates. In this paper, we evaluate ultrasound frame rate requirements for unbiased and robust estimation of tissue displacements and strain. Both tissue-mimicking phantoms under cyclic compressions at rates that mimic the ...
متن کامل