The use of high-efficiency particulate air-filter respirators to protect hospital workers from tuberculosis. A cost-effectiveness analysis.

نویسندگان

  • K A Adal
  • A M Anglim
  • C L Palumbo
  • M G Titus
  • B J Coyner
  • B M Farr
چکیده

BACKGROUND After outbreaks of multidrug-resistant tuberculosis, the Centers for Disease Control and Prevention proposed the use of respirators with high-efficiency particulate air filters (HEPA respirators) as part of isolation precautions against tuberculosis, along with a respiratory-protection program for health care workers that includes medical evaluation, training, and tests of the fit of the respirators. Each HEPA respirator costs between $7.51 and $9.08, about 10 times the cost of respirators currently used. METHODS We conducted a cost-effectiveness analysis using data from the University of Virginia Hospital on exposure to patients with tuberculosis and rates at which the purified-protein-derivative (PPD) skin test became positive in hospital workers. The costs of a respiratory-protection program were based on those of an existing program for workers dealing with hazardous substances. RESULTS During 1992, 11 patients with documented tuberculosis were admitted to our hospital. Eight of 3852 workers (0.2 percent) had PPD tests that became positive. Five of these conversions were believed to be due to the booster phenomenon; one followed unprotected exposure to a patient not yet in isolation; the other two occurred in workers who had never entered a tuberculosis isolation room. These data suggest that it will take more than one year for the use of HEPA respirators to prevent a single conversion of the PPD test. Assuming that one conversion is prevented per year, however, it would take 41 years at out hospital to prevent one case of occupationally acquired tuberculosis, at a cost of $1.3 million to $18.5 million. CONCLUSIONS Given the effectiveness of currently recommended measures to prevent nosocomial transmission of tuberculosis, the addition of HEPA respirators would offer negligible protective efficacy at great cost.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection

Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installat...

متن کامل

Economic Analysis of Implementing Respirator Program or Ventilation System in a Manufacturing Environment

The techniques and methods of developing cost models for respirators are discussed. Models are developed and implemented in this study for nineteen types of respirators in two major classes (air-purifying and supplied-air) and one LEV system. One respirator model is selected for detailed discussion from among the twenty models. The technical cost method is used in constructing the cost models f...

متن کامل

Cost-effectiveness analysis of N95 respirators and medical masks to protect healthcare workers in China from respiratory infections

BACKGROUND There are substantial differences between the costs of medical masks and N95 respirators. Cost-effectiveness analysis is required to assist decision-makers evaluating alternative healthcare worker (HCW) mask/respirator strategies. This study aims to compare the cost-effectiveness of N95 respirators and medical masks for protecting HCWs in Beijing, China. METHODS We developed a cost...

متن کامل

Filter Performance Degradation of Electrostatic N95 and P100 Filtering Facepiece Respirators by Dioctyl Phthalate Aerosol Loading

Polydisperse dioctyl phthalate (DOP) aerosols are employed for testing filter penetration with loading of Rand P-series particulate filters for National Institute for Occupational Safety and Health (NIOSH) certification. Penetration for filters must not exceed NIOSH allowed maximum levels during the entire loading of 200 mg DOP indicating no filter degradation. Degradation of respirators loaded...

متن کامل

Evaluation of Air Filtration Systems to Reduce Aerosol Transmission of PRRS

(1) High-efficiency particulate air (HEPA) filtration: the HEPA-filtration system used a prefilter screen, a bag filter (Eurovent [EU] 8 rating), and a HEPA filter (EU13 rating). (2) 2×-low-cost filtration: The low-cost-filtration system contained mosquito netting (prefilter), 2 fiberglass furnace filters, and 2 electrostatic furnace filters. (3) Bag filtration: Bag filtration involved the use ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 331 3  شماره 

صفحات  -

تاریخ انتشار 1994