Highly Accelerated Free-breathing 4D Cardiac Imaging with CIRCUS Acquisition

نویسندگان

  • Jing Liu
  • Li Feng
  • David Saloner
چکیده

INTRODUCTION 4D cardiovascular MRI applications typically require prolonged scan times and suffer from artifacts due to physiological motion. Compressed sensing (CS) and its combination with parallel imaging (PI) have recently emerged as valuable tools for accelerating MRI acquisitions by reconstructing images from undersampled k-space data. The required incoherent artifact in CS is usually achieved by theoretical random undersampling. In practice, pseudo-random undersampling is implemented. We recently proposed a novel pseudo-random undersampling strategy named CIRcular Cartesian UnderSampling (CIRCUS), which integrates the desirable features of randomization and radial or spiral trajectories on a 3D Cartesian grid. CIRCUS allows easy implementation with flexible selection of pseudo radial, spiral, or random trajectories with specific degree of randomization. It provides high accuracy of image reconstruction and enables favorable interleaving features for 4D cardiovascular imaging. In this study, we will demonstrate highly accelerated 4D whole heart cardiac MRI using a joint multicoil CS reconstruction framework with CIRCUS. MATERIALS AND METHODS Data were acquired from healthy volunteers on a 3.0T MR scanner (GE Medical Systems, Milwaukee, WI) with an 8-channel cardiac coil during free breathing. A 3D gradient-echo sequence with CIRCUS (randomized golden-ratio pseudo radial sampling pattern) was applied, with FOV=320mm, TR/TE=4.0/1.6ms, FA=45°, BW=±125kHz, slice thickness of 4mm, image matrix=256×160×32 (75% partial acquisition in ky&kz), and scan time of 200s. Retrospective cardiac and respiratory gating were applied. Cardiac phases were reconstructed with a temporal resolution of 40 ms (views per segments=10). The interleaving features of CIRCUS allow us to evaluate image reconstruction at different acceleration rates, by retrospectively choosing respiratory gating efficiency (100%, 75%, 50% and 25% tested in this study) and effective scan time (200s and first 120s tested). The undersampled datasets were reconstructed using a multicoil CS reconstruction exploiting joint sparsity along the temporal dimension using a total variation constraint and the corresponding regularization parameters were empirically selected. Image sharpness was evaluated on the left ventricle (LV) cavity-myocardium interface (averaged over 10 points around the LV at end-systolic, earlyand end-diastolic phases). RESULTS & DISCUSSION Highly accelerated free-breathing whole heart 3D CINE imaging was successfully achieved by using the CIRCUS acquisition and the combination of multicoil CS reconstruction methods. Adequate image quality was obtained with various gating efficiencies and acceleration factors (Fig.1). Images obtained with an effective scan time of 200s and respiratory gating efficiency of 50% provided the best image quality, while those with an effective scan time of 120s and 50% gating efficiency also provided comparable results (Fig.2). Clinical cardiac functional measurements are achieved by acquiring 2D CINE images in multiple breath-holds (~5 mins), which often suffer from slice misregistration errors or result in non-diagnostic images in patients with impaired capability of suspending prolonged breathing. The proposed freebreathing 4D cardiac imaging (~2 mins) could be an attractive alternative for evaluating myocardial function with reliable and accurate functional measurements. Further evaluation of the proposed method is ongoing. This 4D technique has also been successfully tested for aorta, liver, and bowel imaging. CONCLUSIONS An effective k-space undersampling scheme has been successfully implemented and applied for highly accelerated 4D whole heart cardiac imaging. REFERENCES 1. Liu J, et al, ISMRM, p3796. 2. Otazo R et al. MRM 2010 Sep;64(3):767-76. 3. Feng L et al, MRM 2013; Jul;70(1):64-74. Fig.1 a) Reconstructed images at end-systole with different acceleration factors. b) Spatial-temporal profile crossing right and left ventricles (a horizontal line on a). c) Comparison of image sharpness.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sub-30 ms real-time, free-breathing cardiac imaging with SPIRiT

Background Combined with Variable density Incoherent SpatioTemporal Acquisition (VISTA, [1]), SPIRiT [2] reconstruction can provide an avenue for highly accelerated real-time, free-breathing cardiac imaging. Yet the high computational cost of iterative algorithms limits practical clinical implementation. The Fast Iterative Shrinkage Thresholding Algorithm (FISTA) [3] can potentially reduce the ...

متن کامل

Model Based Automated 4D Analysis for Real-Time Free-Breathing Cardiac MRI

Background. Cardiac Magnetic Resonance Imaging (CMR) has advanced to provide morphological and functional information even in the presence of variations in cardiac cycle length or for patients having difficulty to hold their breath [5]. Fast and accurate assessment of cardiac function requires precise localization of the structure of interest while taking into account any potential source of er...

متن کامل

Triggered real-time MRI and cardiac applications.

Real-time interactive MRI is becoming the method of choice for many cardiac applications. One current limitation of real-time techniques is inaccurate slice registration during free-breathing. A simple "triggered real-time" imaging approach is proposed which enables the acquisition of synchronized and accurately registered real-time movie loops during short breathholds. Initial in vivo results ...

متن کامل

Steady-state 4D flow using double gating: a healthy volunteer study

Background 4D Phase-Contrast MRI ("4D Flow”) has become a choice modality for assessment of flow patterns in complex vasculatures, such as congenital heart diseases. For thoracic imaging, the technique relies on ECG-triggering and an imaging navigator to compensate for breathing motion [Markl-JMRI2007]. The acquisition of the navigator requires switching off the 4D flow acquisition, thus breaki...

متن کامل

Sub-8-minute cardiac four dimensional flow MRI using kat ARC and variable density signal averaging

Background Recently, 3D CINE phase-contrast MRI (4D Flow) has demonstrated potential for quantitative measurement of blood flow of the cardiovascular systems in the entire thoracic trunk [1]. However, the needs of 4D flow for high resolution, large volume coverage & respiratory gating render very long scan time. This work intended to improve the data acquisition efficiency of free-breathing car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013