Enigma: Actions involved in the 'Double Stepping' of the Middle Rotor

نویسنده

  • David H. Hamer
چکیده

In this description of the Enigma rotor movement sequence the following conventions have been adopted. The three rotors are numbered from right to left as seen from the machine operator’s viewpoint thus, the ‘fast’ or right hand rotor is Rotor 1, Rotor 2 is in the middle position and the ‘slow’ or left hand rotor is Rotor 3. The associated ratchets, stepping levers and notches are similarly designated. e.g. Ratchet 3 is attached to Rotor 3, the primary function of Lever 1 is to move Rotor 1; Notch 2 is on the index ring of Rotor 2; ...and so on. Following this same convention, “left” and “right” in the body of the article are as seen from the viewpoint of the Enigma keyboard operator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryptanalysis of Typex

Rotor cipher machines played a large role in World War II: Germany used Enigma; America created Sigaba; Britain developed Typex. The breaking of Enigma by Polish and (later) British cryptanalysts had an enormous impact on the war. However, despite being based on the commercial version of the Enigma, there is no documented successful attack on Typex during its time in service. This paper covers ...

متن کامل

Enigma G-111

• Wiring for Wheel II corrected. • Mentioning of double stepping anomaly added to chapter 1.3 and 1.4. • Sizes in 2nd drawing on page 22 corrected. • Some minor corrections of text and typos. • Apendix A-E removed.

متن کامل

Robust Control of a Quadrotor in the Presence of Actuators' Failure

Today, robots and unmanned aerial vehicles are being used extensively in modern societies. Due to a wide range of applications, it has attracted much attention among scientists over the past decades. This paper deals with the problem of the stability of a four-rotor flying robot called quadrotor, which is an under-actuated system, in the presence of operator or sensor failures. The dynamica...

متن کامل

Performance Analysis of Disk Type Variable Reluctance Resolver under Mechanical and Electrical Faults

Disk Type Variable Reluctance (DTVR) resolvers have distinguished performance under run out fault comparing to conventional sinusoidal rotor resolvers. However, their accuracy under inclined rotor fault along with different types of eccentricities includes static and dynamic eccentricities are questioned. Furthermore, due to thin copper wires that are used for signal and excitation coils of res...

متن کامل

Dynamic Analysis of A Three-Rotor Flexible Coupling with Angular Misalignment

In this paper, the dynamic response of a three-rotor flexible coupling to the angularmisalignment has been studied. The coupling is a power transmission agent between the motor andgearbox, in the power transmission system of SAG Mill (semi autogenously mill) in the Gol-e-Gohariron ore complex in Sirjan, Iran. Degrees of freedom of the system are the model's lateral deflectionsand the rigid-body...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cryptologia

دوره 21  شماره 

صفحات  -

تاریخ انتشار 1997