Self-monitoring of blood glucose in Type 2 diabetes: cross-sectional analyses in 1993, 1999 and 2009.
نویسندگان
چکیده
AIM To characterize the numbers of reagent strips dispensed for self-monitoring of blood glucose to patients with Type 2 diabetes in Tayside, Scotland, in 1993, 1999 and 2009. METHODS A diabetes clinical information system in Tayside, record-linked to electronic dispensed prescribing records, was used to collate all dispensed prescribing records for three cross-sectional samples of patients with Type 2 diabetes in 1993 (n = 5728), 1999 (n = 8109) and at 1 January 2009 (n = 16,450). The numbers of reagent strips dispensed during the relevant calendar year were calculated and patients stratified by treatment. We also explored whether age, sex or material and social deprivation were associated with whether a patient received strips. RESULTS Proportions of people who received self-monitoring reagent strips increased from 15.5% in 1993, to 24.2% in 1999 to 29.8% in 2009, as did numbers of strips dispensed. While the proportion of diet-treated patients who received reagent strips was still very low in 2009 (5.6%), the proportion among those treated with oral agents tripled from 9.4 to 27.4% between 1993 and 2009. Over 90% of patients treated with insulin received reagent strips and, among non-insulin-treated patients, this was more common among women, younger people and less deprived groups. CONCLUSIONS The numbers of reagent strips dispensed for self-monitoring of blood glucose has increased and almost all insulin-treated patients receive strips. While few diet-treated patients receive strips, they are more extensively dispensed to those treated with oral agents. Given that self-monitoring of blood glucose is no longer routinely recommended in non-insulin treated patients, strategies to reduce unnecessary dispensing of reagent strips are needed.
منابع مشابه
Does patient blood glucose monitoring improve diabetes control? A systematic review of the literature.
OBJECTIVE The purpose of this systematic review was 2-fold: first, to perform a comprehensive review of relevant studies on the impact of self-monitoring of blood glucose (SMBG) on HbA1c levels for patients with type 2 diabetes mellitus and, second, to explore mediators and moderators within a self-regulation framework. DATA SOURCES Five databases-Medline, PsychInfo, Cochrane Database of Syst...
متن کاملEvaluation of Fasting Blood Sugar via Salivary Glucose in Type 2 Diabetes Mellitus
Objective: Diabetes mellitus (DM) as an ongoing metabolic disorder worldwide is a major public health concern. Diagnosis of DM is depended on clinical symptoms and laboratory findings. Fasting blood glucose (FBG) monitoring is currently the most common diagnostic method, which is an invasive and stressful procedure. Most recently, the use of non-invasive, convenient methods like fasting salivar...
متن کاملبررسی موانع موثر بر رفتارهای خود مراقبتی بیماران دیابتی نوع 2 استان یزد، در سال 1393
Introduction: Patients with diabetes may have weakness in performing appropriate self-care behaviors and adherence to it. Therefore, the first step to the improvement of self-care behaviors is to identify the influential barriers to the self-care behaviors. This study aimed to determine the barriers of self-care behaviors in type 2 diabetic patients of Yazd province. Methods: This was a ...
متن کاملThe survey of abnormal glucose tolerance and insulin resistace and incidence of diabetes type 2 in poly cystic ovary syndrome patients in Shiraz
Background: Polycystic ovarian syndrome is one of the most commen hyper androgenic disorders affecting women, its prevalence being estimated at 5% – 10%. Our goal was to survey abnormal glucose tolerance, insulin resistance and incidence of diabetes type 2 in patients with polycystic ovary syndrome. Materials and methods: This investigation is a descriptive – analytic study which is done to su...
متن کاملFrequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database.
OBJECTIVES To investigate patterns of self monitoring of blood glucose concentration in diabetic patients who use insulin and to determine whether frequency of self monitoring is related to glycaemic control. SETTING Diabetes database, Tayside, Scotland. SUBJECTS Patients resident in Tayside in 1993-5 who were using insulin and were registered on the database and diagnosed with insulin depe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diabetic medicine : a journal of the British Diabetic Association
دوره 29 6 شماره
صفحات -
تاریخ انتشار 2012