Considerations on electrical impedance measurements of electrolyte solutions in a four- electrode cell

نویسندگان

  • C V Chaparro
  • L V Herrera
  • A M Meléndez
  • D A Miranda
چکیده

A tetrapolar probe to measure the electrical properties of electrolyte solutions was implemented with gold electrodes according to the van der Pauw method. Electrical impedance spectroscopy (EIS) measurements of different concentrations of phosphate buffer saline (PBS) solution and an oral mucosal tissue sample dispersed in PBS were performed in the galvanostatic mode using a four-electrode cell (tetrapolar probe). Taking advantage of using a potentiostat/galvanostat for carrying out the electrical measurements, a simple and rapid method using a three-electrode electrochemical cell is described for: a) cleaning of electrodes, b) verification of surface chemical state of electrode material and c) choice of current supplied to electrodes for EIS measurements. Results of this research shown a depolarization effect due to the addition of oral mucosa tissue cells into the PBS solution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local electrochemical impedance spectroscopy: Considerations about the cell geometry

Local electrochemical impedance spectroscopy provides a powerful tool for the investigation of surface heterogeneities on electrode surfaces. However, measurements are greatly influenced by geometry-induced frequency dispersion. In order to account for this frequency dispersion, both simulations and experiments were performed to explore the influence of a recessed electrode on the local and glo...

متن کامل

Microfabricated Thin Film Impedance Sensor & AC Impedance Measurements

Thin film microfabrication technique was employed to fabricate a platinum based parallel-electrode structured impedance sensor. Electrochemical impedance spectroscopy (EIS) and equivalent circuit analysis of the small amplitude (±5 mV) AC impedance measurements (frequency range: 1 MHz to 0.1 Hz) at ambient temperature were carried out. Testing media include 0.001 M, 0.01 M, 0.1 M NaCl and KCl s...

متن کامل

Electrical impedance tomography methods for miniaturised 3D systems

In this study, we explore the potential of electrical impedance tomography (EIT) for miniaturised 3D samples to provide a noninvasive approach for future applications in tissue engineering and 3D cell culturing. We evaluated two different electrode configurations using an array of nine circular chambers (Ø 10 mm), each having eight gold plated needle electrodes vertically integrated along the c...

متن کامل

Investigation of Hydroxylated Carbon Felt Electrode in Vanadium Redox Flow Battery by Using Optimized Supporting Electrolyte

Traditional vanadium batteries use pure sulfuric acid as electrolyte, but H2SO4 does not absorb enough vanadium ions to make the electrolyte an efficient energy source. This study investigates the effect of hydroxylation process on electrochemical and operational properties of carbon felt electrode in VOSO4 solution with an optimized supporting electrolyte (a mixture of six parts HCl and 2.5 pa...

متن کامل

Traveling-wave electrokinetic micropumps: velocity, electrical current, and impedance measurements.

An array of microelectrodes covered in an electrolyte and energized by a traveling-wave potential produces net movement of the fluid. Arrays of platinum microelectrodes of two different characteristic sizes have been studied. For both sizes of arrays, at low voltages (<2 V pp) the electrolyte flow is in qualitative agreement with the linear theory of ac electroosmosis. At voltages above a thres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015