چکیده
We describe the application of the microencapsulated-antibody technique to the radioimmunoassay of digoxin in serum. Droplets of emulsified rabbit antibody are microencapsulated in a semipermeable nylon membrane by an interfacial polymerization technique. The antibody microcapsules are incubated with 125I-labeled digoxin and unlabeled digoxin for 15 min at 37 degrees C, then free and bound digoxin are separated by centrifugation. Subtherapeutic, therapeutic, and toxic concentrations of digoxin in sera can be determined, with use of a standard curve prepared by use of known amounts of digoxin. With this technique we obtained an intra-laboratory correlation coefficient of 0.945 for 100 patients' sera and one of 0.940 for interlaboratory results for 21 sera (10 laboratories) when compared to a routine clinical laboratory radioimmunoassay for digoxin. Icterus, lipemia, hemoglobin, or disproteinemia had no effect on the analytical recovery of digoxin. The standard curve was linear to 6 microgram/L; the sensitivity was 0.25 microgram/L.
منابع مشابه
Application of radioimmunoassay technique for determination of antigen concentration in different cells with a new monoclonal antibody [Persian]
Introduction: Binding a monoclonal antibody to tumor associated antigens is an effective method for cancer therapy because these agents can specifically target malignant cells, in fact monoclonal antibodies are effective agents for diagnosis, grading and treatment of different kinds of cancers. Methods: In this research, a new monoclonal antibody against colon cancer cells was prepared an...
متن کاملAssessment of Abnormal Serum Digoxin Concentration
ABSTRACT Cardiac glycosides have been used in the management of heart failure for more than 200 years and remain the only drug currently available for Long-term ambulatory use that have positive inotropic effect. The relatively narrow therapeutic- index of cardiac glycosides renders them particularly difficult to use, and the clinician should have a detailed understanding of the actions and ph...
متن کاملAwaiwl of diioxin bioavailabitity and phamecokinstics in relation to cardiac therapy
Butler and Chen’ first reported on the preparation of digoxin-specific antibodies. Later, Smith and associates2s3 characterized the antibodies2 and developed a radioimmunoassay for digoxin in serum or plasma.3 Subsequently, it was shown that antibodies present in commerciaIly available antiserum were not specific for digoxin, but that digoxin, digoxigen-mono-digotoxoside, and digoxigen-bis-digi...
متن کاملRadioimmunoassay Measurement of Serum Cardiac Glycoside Levels: Using Pharmacologic Principles to Solve Crossreactivity Problems
Laboratories performing analyses for serum cardiac glycosides are sometimes faced with the problem of distinguishing between digoxin and digitoxin in a specimen. The antibodies to the cardiac glycosides supplied with radioimmunoassay kits for these drugs have some measurable degree of cross reactivity. Therapeutic levels of digitoxin are approximately ten times greater than those of digoxin, an...
متن کاملRadioimmunoassay and enzyme immunoassay compared for determination of digoxin.
Patients' sera were analyzed for digoxin by using two different radioimmunoassays and an enzyme immunoassay. Quantitative results obtained by enzyme immunoassay (I) were compared to results obtained on aliquots of the same sample by the radioimmunoassays (II and III). The correlation coefficients were: I vs. II 0.90, n=108; I vs. III 0.94, n=102; and II vs. III 0.95, n=158. Day-to-day precision...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 6 شماره
صفحات -
تاریخ انتشار 1979