Soft Tissue Modeling from 3D Scanned Data

نویسنده

  • Jean-Christophe Nebel
چکیده

Human body 3D scanners are becoming a mature technology that generates accurate static photo-realistic 3D models of real human beings. However the data collected allow only the construction of the outer surface of the body. In this paper we describe how from 3D surface data we generate 3D volumetric meshes of soft tissues suitable for the finite element method (FEM). We then deform these meshes using our implementation of the FEM for 3D volumetric meshes. Finally we present some experimental results of the deformation of a human body and detail a methodology to evaluate the distribution of soft tissue layers from a 3D scan of a specific individual.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soft Tissue Modeling Using ANFIS for Training Diagnosis of Breast Cancer in Haptic Simulator

Soft tissue modeling for the creation of a haptic simulator for training medical skills has been the focus of many attempts up to now. In soft tissue modeling the most important parameter considered is its being real-time, as well as its accuracy and sensitivity. In this paper, ANFIS approach is used to present a nonlinear model for soft tissue. The required data for training the neuro-fuzzy mo...

متن کامل

Soft tissue modelling from 3D scanned data

Human body 3D scanners are becoming a mature technology that generates accurate static photo-realistic 3D models of real human beings. However the data collected allow only the construction of the outer surface of the body. In this paper we describe how from 3D surface data we generate 3D volumetric meshes of soft tissues suitable for the finite element method (FEM). We then deform these meshes...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Modeling of Tactile Detection of an Artery in a Soft Tissue by Finite Element Analysis

Nowadays, one of the main problems encountered in minimally invasive surgery and telesurgery is the detection of arteries in tissue. In this study, for the first time, tactile detection of an artery in tissue and distinguishing it from the tumor has been modeled by finite element method. In this modeling, three 2D models of tissue have been created: tissue, tissue including a tumor, and tissue ...

متن کامل

Evaluation of Soft Tissue Sarcoma Tumors Electrical Conductivity Anisotropy Using Diffusion Tensor Imaging for Numerical Modeling on Electroporation

Introduction: There is many ways to assessing the electrical conductivity anisotropyof a tumor. Applying the values of tissue electrical conductivity anisotropyis crucial in numerical modeling of the electric and thermal field distribution in electroporationtreatments. This study aims to calculate the tissues electrical conductivityanisotropy in patients with sarcoma tumors using diffusion tens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000