A study of the effects of heater size, subcooling, and gravity level on pool boiling heat transfer
نویسندگان
چکیده
Pool boiling heat transfer measurements from different heater sizes were obtained in low-g (0.01± 0.025 g) and high-g (1.7 ± 0.5 g) aboard the KC-135 aircraft. Boiling on three heaters of different size (0.65, 2.62, 7.29 mm) was studied. Control circuitry was used to maintain an isothermal boundary condition on the heater surface while the power dissipated by the heater was measured. Steadystate boiling data in low-g and high-g were obtained for various bulk fluid subcoolings and wall superheats. For the two larger heaters in low-g, critical heat flux (CHF) increased with increasing bulk subcooling and is significantly smaller than the CHF obtained in high-g. Satellite bubble coalescence with the primary bubble was the mechanism by which CHF occurred in low-g for larger heaters. At high subcoolings and wall superheats, above that of which CHF occurred, the onset of strong thermocapillary convection caused an increase in heat transfer above CHF. For the small heater in low-g, bulk subcooling had a negligible impact on boiling performance and a characteristically low heat flux was observed for the CHF. In high-g, boiling on heaters roughly the size of the bubble departure diameter was dominated by surface tension and characterized by a very low bubble departure frequency. For larger heaters in high-g, bubble departure frequency decreased with increasing subcooling but time and surface averaged heat transfer remained unaffected. 2003 Elsevier Inc. All rights reserved.
منابع مشابه
Pool boiling heat transfer on small heaters: effect of gravity and subcooling
Measurements of space and time resolved subcooled pool boiling of FC-72 in low, earth, and high gravity environments were made using a microscale heater array. Data from each heater in the array were synchronized with highspeed digital video. The boiling behavior was dominated by the formation of a large primary bubble on the surface which acted as a ‘‘sink’’ for many smaller bubbles surroundin...
متن کاملNumerical Simulation and Experimental Validation of the Dynamics of a Single Bubble During Pool Boiling Under Constant and Time-Varying Reduced Gravity Conditions
The numerical simulation and experimental validations of the growth and departure of a single bubble on a horizontal heated surface during pool boiling under reduced gravity conditions have been performed here. A finite difference scheme is used to solve the equations governing mass, momentum and energy in the vapor liquid phases. The vaporliquid interface is captured by level set method, which...
متن کاملHeater size and heater aspect ratio effects on subcooled pool boiling heat transfer in low - g
Pool boiling heat transfer measurements using heaters of varying aspect ratio were obtained in low-g (0.01 g ± 0.025 g) aboard the KC-135 aircraft. The heater aspect ratio was varied by selectively powering 2 · 2, 2 · 4, 2 · 6, 2 · 8, and 2 · 10 arrays of heaters in a 10 · 10 heater array containing individual heaters 0.7 · 0.7 mm in size. Electronic control circuitry was used to maintain an is...
متن کاملPool boiling heat transfer coefficient of pure liquids using dimensional analysis
The pool boiling heat transfer coefficient of pure liquids were experimentally measured on a horizontal bar heater at atmospheric pressure. These measurements were conducted for more than three hundred data in thermal currents up to 350 kW.m-2. Original correlations and the unique effect of these correlations on experimental data were discussed briefly. According to the analysis, a new empirica...
متن کاملCriteria for approximating certain microgravity flow boiling characteristics in Earth gravity.
The forces governing flow boiling, aside from system pressure, are buoyancy, liquid momentum, interfacial surface tensions, and liquid viscosity. Guidance for approximating certain aspects of the flow boiling process in microgravity can be obtained in Earth gravity research by the imposition of a liquid velocity parallel to a flat heater surface in the inverted position, horizontal, or nearly h...
متن کامل