Development of square-wave adsorptive stripping voltammetric method for determination of acebutolol in pharmaceutical formulations and biological fluids
نویسندگان
چکیده
A validated simple, rapid, sensitive and specific square-wave voltammetric technique is described for the determination of acebutolol (AC) following its accumulation onto a hanging mercury drop electrode in a Britton-Robinson universal buffer of pH 7.5. The optimal procedural conditions were: accumulation potential Eacc = - 0.8 V versus Ag/AgCl/KCl, accumulation duration tacc = 30 s, pulse-amplitude = 70 mV, scan rate = 100 mV/s, frequency = 30 Hz, surface area of the working electrode = 0.6 mm2 and the convection rate = 2000 rpm. Under these optimized conditions, the adsorptive stripping voltammetry (AdSV) peak current was proportional over the concentration range 5 × 10-7 - 6 × 10-6 M (r = 0.999). Recoveries for acebutolol from human plasma and urine were in the range 97-103% and 96-104% respectively. The method proved to be precise (intra-day precision expressed as %RSD in human plasma ranged from 2.9 - 3.2% and inter-day precision expressed as %RSD ranged from 3.4 - 3.8%) and accurate (intra-day accuracies expressed as % error in human urine ranged from -3.3 - 2.8% and inter-day accuracies ranged from -3.3 - 1.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for acebutolol were 1.7 × 10-7 and 5 × 10-7 M, respectively. Possible interferences by substances usually present in the pharmaceutical formulations were investigated with a mean recovery of 101.6 ± 0.64%. Results of the developed square-wave adsorptive stripping voltammetry (SW-AdSV) method were comparable with those obtained by reference analytical method.
منابع مشابه
A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the...
متن کاملAdsorptive Cathodic Stripping Voltammetric Determination of Ciprofloxacin in Bulk Powder, Pharmaceutical Dosage Forms and Urine
Purpose: To investigate the electro-reduction behaviour and determination of ciprofloxacin using a hanging mercury drop electrode. Methods: Cyclic voltammograms of ciprofloxacin recorded in Britton – Robinson buffers pH 2 – 5 exhibit a single irreversible cathodic peak. The dependence of the peak current and peak potential values on buffer (nature, pH and concentration) and accumulation conditi...
متن کاملAdsorptive Stripping Anodic Voltammetric Determination of Thioctic Acid in Bulk and Pharmaceutical Formulations
The electrochemical behavior of thioctic acid at the hanging mercury drop electrode was studied in different supporting electrolytes. In Britton - Robinson buffer pH 3.29, the square - wave adsorptive anodic stripping voltammogram of thioctic acid exhibited a single well - defined anodic peak at about -0.21 V vs Ag/AgCl. The peak response was characterized with respect to pH, preconcentration t...
متن کاملAdsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملVoltammetric behavior of lercanidipine and anodic adsorptive stripping voltammetric method for assay in pharmaceutical dosage forms and biological fluids
Electrochemistry of lercanidipine (LCN) was investigated and its optimal conditions were evaluated based on the irreversible and diffusion-controlled electrochemical oxidation signal (+ 0.93 V) of a carbon paste electrode (CPE) versus Ag/AgCl in Britton Robinson buffer (BR) and ethanol mixture of pH 4.5. Electrochemical determination was performed by square wave anodic adsorptive stripping volt...
متن کامل