Highly selective iodide electrode based on the copper(II)-N,N'-bis(salicylidene)-1,2-bis(p-aminophenoxy)ethane tetradentate complex.
نویسندگان
چکیده
In this paper, a new PVC-based liquid-membrane anion-selective electrode based on a copper(II) of N,N'-bis(salicylidene)-1,2-bis(p-aminophenoxy)ethane tetradentate complex (Cu(II)BBAP) is described, which displays a preferential potentiometric response to iodide ion at pH 2.0 and an anti-Hofmeister selectivity sequence: I->SCN->ClO4->NO2->H2PO4->NO3->SO4(2-)>Br->Cl-. The electrode exhibits a near-Nernstian potential linear range of 8.2x10(-7)-1.0x10(-1) M with a detection limit of 5.3x10(-7) M and a slope of -58.8 mV per decade. The A.C. impedance technique and the UV/Vis spectroscopy technique were used to analyze the response mechanism. The electrode could be applied to determine iodide in medicine analysis, and the obtained results were fairly satisfactory.
منابع مشابه
Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
متن کاملThermodynamic study of Cu(II) ion-selective membrane electrode based on his (N-salicylidene-3,32-diamino dip hen y sulfone
The effect or temperature on the behavior of Cu(II) Mr electrode based on bis(N-sahcylidenc-3.3'-4iaminodiphenyl) sulfune(BSDDS) was studied. This electrode showed a good Nemstian response in the temperaturerange of 20-50 C. Also, the behavior of the synthesized electrode was inngigated in the mixed solvents'ethanol+water" and "dioxane +water'.
متن کاملCu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone
In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...
متن کامل(1E,2E) -bis (2-aminophenyl) N'1,N'2-dihydroxyethane bis (imidothioate) as a neutral carrier in ion-selective electrode for Ni(II) and it computational studies
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
متن کاملCopper(II) complexes of a series of polypyridine ligands possessing a 1,2-bis(2-pyridyl)ethane common moiety: incorporation and hydrolysis of phosphate esters.
Two tetradentate ligands 1,2-bis[2-((dimethylamino)methyl)-6-pyridyl]ethane (L1) and 1,2-bis[2-(N-piperidinomethyl)-6-pyridyl]ethane (L2) and a hexadentate ligand 1,2-bis(2-((methyl(pyridylmethyl)amino)methyl)-6-pyridyl)ethane (L3) were prepared as part of a series of new polypyridine ligands possessing a 1,2-bis(2-pyridyl)ethane common moiety. L1 and L2 form mononuclear Cu(II) complexes [Cu(L)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 10 شماره
صفحات -
تاریخ انتشار 2006