Tracheal tubes and connectors used in neonates--dimensions and resistance to breathing.

نویسنده

  • D J Hatch
چکیده

The dimensions of tracheal tubes and connectors in common use were measured together with the resistance to breathing at flow rates occurring in babies breathing quietly. The outside diameters of rubber tubes varied more than those of plastic tubes. The main factors influencing resistance were the internal diameter and a sudden change in diameter or direction of flow. These are of particular importance in tubes of 2.5 mm i.d. and less and may cause an increase in the work of breathing during spontaneous ventilation. The resistance of small Cole pattern tubes was greater than that of plain tubes of similar o.d.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling the mechanical effects of tracheal tubes in normal subjects.

The addition of tracheal tubes to the respiratory system contributes an extra mechanical burden in terms of pressure necessary to overcome its own resistance. On the basis of experimental data from the literature and on a previously reported mathematical model of the inspirogram, we wished to study predictions of pressures, volume, flow and work of breathing during the use of tracheal tubes. Th...

متن کامل

Shiley Flexible Adult Tracheostomy Tubes vs. Shiley DCT and FEN Tracheostomy Tubes

Tracheostomy can influence the work of breathing by introducing additional resistance to airflow through the native airway. In a 1996 study, Hussey and Bishop determined that the presence of a deflated cuff in the airway significantly increased the work of breathing and theorized that a lower profile cuff would introduce less resistance to airflow. Hussey and Bishop also demonstrated that the p...

متن کامل

Effects of a closed system suction connector on airway resistance in ventilated neonates.

BACKGROUND/AIM Increased airway resistance reduces the effectiveness of ventilation treatment. Endotracheal tubes (ETTs) and connectors contribute to resistance. However, the effect of a closed system suction (CSS) connector is not well known. We compared the in vivo resistance occurring with a CSS connector with that of the standard connector. MATERIALS AND METHODS This prospective study was...

متن کامل

Changes in orofacial muscle activity in response to changes in respiratory resistance.

Increased resistance in the upper airway is known to be a contributing factor to deviant facial growth patterns. These patterns are the result of a prolonged presence of unbalanced oropharyngeal muscle activity. We hypothesized that mechanically increasing airway resistance would enhance the activity of the muscles facilitating respiration, and we attempted to demonstrate that the increased mus...

متن کامل

Anesthesia machine breathing tube holder

dotracheal tube and are composed of inspiratory and expiratory corrugated limbs. The two breathing tubes carry respiratory gases with volatile anesthetics to and from patients during general anesthesia. Although longer corrugated breathing tubes allow the anesthesia machine to be located farther from the patients, they are so long and flexible that they tend to hang down below the operating tab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 50 9  شماره 

صفحات  -

تاریخ انتشار 1978